Nilfisk-Advance America SR 5110 P/B Manuel D’Utilisation

Page de 30
S31NUK5120(3)2001-04
Warning: the following interventions must be done with machine in Off condition and master key 
out. All the periodic maintenance operations must be performed by skilled personnel or 
by an authorized service centre.
Every maintenance intervention on the petrol engine must be performed in agreement with the 
engine User Manual.
Note: the battery life will depend on a good periodic maintenance (check of the level of the 
electrolyte and of battery voltage). Besides it must be taken into account that an unused 
battery is submitted to a self-discharge phenomenon. In the event that the machine is not 
used for a long time (e.g. 3 or 4 weeks) it is necessary TO RECHARGE THE BATTERY; 
infact the battery voltage MUST NEVER drop down below 20 Volt.
SUMMARY OF MAINTENANCE 
CONTROLS (petrol version)
24
For SR1100: 3200 engine shaft RPM with no function working and battery voltage higher than 27 
Volt
For SR 1200: 3300 engine shaft RPM with no function working and battery voltage higher than 27 
Volt
(+) 20 hours or not more than 1 month
(++) 100 hours or not more than 8 months
CONTROL
UPON 
DELIVERY
TWO 
TIMES PER 
WEEK
ONE
TIME PER 
WEEK
EVERY 
20 
HOURS
EVERY 
50 
HOURS
EVERY 
100 
HOURS
EVERY 
400 
HOURS
Battery liquid level and voltage 
check
Engine air filter cleaning
Panel filter cleaning
Engine oil level check
1
st
 TIME
Engine oil replacement
● (+)
1
st
 TIME 
● (++)
Engine RPM check and 
adjustment (*)
Check the carbon brushes of all 
electrical motors and replace 
them if worn
Belt tension
Brake adjustment
Filter shaker
Nut and screw tightness
Wear of main brush and side 
brushes
Sealing of gaskets of filter 
compartment and of flaps
Clean the steering chain and 
(SR 1200 - SR 5120 only) the 
traction wheels chains with gas-
oil or a proper solvent.