List of Datapoint Attributes 
Different attributes are assigned to each datapoint type. Table 17, Table 18, and 
Table 19 list the attributes assigned to the various datapoint types: 
 
Table 17. Datapoint attributes 
 
analog input 
analog output 
digital input 
digital output 
digital output (pulse 1) 
User Address 
User Address 
User Address 
User Address 
User Address 
Descriptor 
Descriptor 
Descriptor 
Descriptor 
Descriptor 
Technical Address 
Technical Address 
Technical Address 
Technical Address 
Technical Address 
Suppress Point 
Suppress Point 
Suppress Point 
Suppress Point 
Suppress Point 
Access Level 
Access Level 
Access Level 
Access Level 
Access Level 
Write Protection 
Write Protection 
Write Protection 
Write Protection 
Write Protection 
Operating Mode 
Operating Mode 
Operating Mode 
Operating Mode 
Operating Mode 
Value 
Value 
Value 
Value 
Value 
Manual Value 
Manual Value 
Manual Value 
Manual Value 
Manual Value 
Engineering Unit 
Engineering Unit 
Alarm Delay 
Alarm Type 
Alarm Type 
I/O Characteristic 
I/O Characteristic 
Alarm Type 
Alarm Reporting 
Alarm Reporting 
Sensor Offset 
Alarm Reporting 
Alarm Status 
Trend Logging 
Trend Logging 
Low Warning Limit 
Trend Logging 
Point in Alarm 
Hours Run Log 
Hours Run Log 
Low Alarm Limit 
Subtype 
Alarm Reporting 
Hours Run 
Hours Run 
High Warning Limit 
Time to Open 
Trend Logging 
Service Interval 
Pulse Duration 
High Alarm Limit 
Time to Close 
Hours Run Log 
Hours Since Serviced 
Service Interval 
Alarm Delay 
Trend Hysteresis 
Hours Run 
Active State 
Hours Since Serviced 
Alarm Type 
Trend Cycle 
Service Interval 
Active State Text 
Active State 
Point in Alarm 
Suppress Alarm 
Hours Since Serviced 
Passive State Text 
Active State Text 
Alarm Reporting 
NV Name and Index 
Active State 
Cycle Count 
Passive State Text 
Trend Logging 
Safety Position
1
 
Active State Text 
Last Changed 
Cycle Count 
Alarm Status 
changed 
 
Passive State Text 
Subtype 
Last Changed 
Alarm Hysteresis 
 
Last Changed 
Suppress Alarm 
Subtype 
Trend Hysteresis 
 
Cycle Count 
 
Suppress Alarm 
Trend Cycle 
 
Suppress Alarm 
 
NV Name and Index * 
 
 
Normally Open / 
Normally Closed 
Normally Open / 
Normally Closed 
 
Suppress Alarm 
 
NV Name and Index * 
NV Name and Index * 
 
NV Name and Index * 
 
LED Mode
1
 
Safety Position
1
 
 
* Read-only attribute. Changing the NV name and index requires changing the datapoint to NV mapping in CARE. 
1
Excel 800, only.