A fireplace equipped with glass doors operates 
mush differently than a fireplace with an open 
front. A fireplace with glass doors has a limited 
amount of air for combustion. Excessive heat 
within the fireplace can result if too large a fire 
is built or if the combustion air gate is not com-
pletely open. 
The following tips should be followed to assure 
that both the fireplace and the glass door retain 
their beauty and function properly. Both the flue 
damper and the glass doors must be fully opened 
before starting the fire. This will provide sufficient 
combustion air and maintain safe temperatures in 
the firebox.
IMPORTANT:
 The  glass  must  be  allowed  to 
warm slowly and evenly. The tempered glass will 
withstand a gradual temperature rise to 550° F, 
which is more than a normal fire will generate. 
Such materials as pitch/wax laden logs, very dry 
mill end lumber and large amounts of paper or 
cardboard boxes can create an excessively hot fire 
and should not be burned in this fireplace. Always 
keep the fire well back from the doors and never 
allow flames to contact the glass.
  WARNING:  Fireplaces 
equipped  with  glass  doors 
should  be  operated  only  with 
doors fully opened or doors fully 
closed. Doors, if left partly open, 
may draw gas and flame out of 
the  fireplace  opening  creating 
risks of both fire and smoke.
Cleaning the Glass
Clean the glass with any commercial glass cleaner 
or soap and water. Do not use any abrasive mate-
rial to clean the glass. Do not clean the glass with 
any cool water is the glass is still hot from the 
fire and smoke.
A gas line or gas log lighter may be installed for the 
purpose of installing a vented or vent-free decorative 
gas appliance incorporating an automatic shutoff de-
vice and complying with the Standard for Decorative 
Gas Appliances for Installation in Vented Fireplaces, 
ANSI Z21.60 or American Gas Association draft re-
quirements for Gas Fired Log Lighters for Wood Burn-
ing Fireplaces, Draft NO. 4 dated August, 1993.
OpeRatiOn and 
Maintenance 
guidelineS
Continued
If you wish to install an unvented (vent-free) gas 
log set, only unvented gas log sets which have been 
found to comply with the standard for unvented 
room heaters, ANSI Z21.11.2 are to be installed 
in this fireplace.
OUTSIDE AIR AND DAMPER 
HANDLE OPERATION
The damper handle, which opens and closes the 
damper blade, is located in the upper front face of 
the fireplace. Pushing the handle into the left of the 
keyway slot will free the damper blade to automati-
cally open. Pushing the handle in to the right will 
lock the damper blade closed (see Figure 22).
The outside air kit handle is located at the left hand 
side of the fireplace (see Figure 22). Pulling the 
handle out will free the outside air door to open. 
Pushing the handle in will lock the door closed. 
 WARNING: Risk of fire! Replace 
grate with DESA model 111100-01 
only. This grate has been designed 
to keep the operation of your fire-
place safe and efficient.
For further operating guidelines, instructions and 
warranty information, please refer to your home-
owner's guide or contact your authorized dealer.
tecHnical SeRVice
You may have further questions about installation, 
operation, or troubleshooting. If so, contact DESA’s 
Technical Service Department at 1-866-672-6040. 
When calling please have your model and serial 
numbers of your heater ready.
You can also visit DESA’s technical services web 
site at www.desatech.com.
Figure 22 - Damper and Air Kit Handle