3.4 Baud Rate Setting (GP-1650DF only)
1. Press the [MENU] key.
2. Press the software key labeled "GPS/DGPS/TD OPTIONS".
3. Press the software key labeled "DGPS SETUP OPTIONS" to dis-
play the following message.
s FORMAT
NMEA 0183
   VER 1.5
DGPS 3D
DGPS
OPTION
RETURN
   DGPS MODE
ON
   BEACON FREQUENCY
AUTO
s
BEACON BAUD RATE
AUTO
   DGPS ALARM
OFF
EDIT
Figure 3-5  DGPS Setup Options Display
4. Confirm that "ON" is selected at "DGPS MODE" field for GP-
1650DF.
5. Select "BEACON BAUD RATE" by the arrow key.
6. Press the software key labeled "EDIT" to display the following
message. Beacon baud rate cannot be set when "BEACON
FREQUENTRY" is set to "AUTO".
BEACON BAUD RATE
     
200
100
     
50
Figure 3-6  Beacon Baud Rate Display
7. Select beacon baud rate corresponding to DGPS reference sta-
tion to use.
8. Press the [ENTER] key.
9. Press the [PLOT] key to finish.