Furuno 10n Manuel D’Utilisation

Page de 33
 
 
 17 
2.3 Optional 50 kHz and 200 kHz Transducers 
To connect optional transducer 50B-6, 50B-6B, 50B-6G, 50B-62M, 50B-9B, 50B-92M, 
200B-5, 200B-5S, 50/200-1T or 50/200-12M, the optional Distribution Box (MB-1000, code 
no. 000-040-809) is required. Additionally, a cable assembly (02S4089, code no. 
000-133-622) is required to connect to the network sounder. Fasten the cable from the 
Distribution Box to the XDR connector on the network sounder. 
 
To network sounder
(cable is fitted with
8P connector.
8P-10P converter
connector is re-
quired.)
Shield
TRANSDUCER
50B-6/6B/6G
50B-62M
50B-9B
50B-92M
200B-5/5S
50kHz
200kHz
SHIELD
RED
RED
BLK
BLK
TB2
1
2
3
4
5
J2          J1
BLK
3
2
1
WHT
TB1
02P6168
Jumper block setting
J2: Full power output
J1: Reduced output
(SHIELD)
(RED)
(BLU)
(GRN)
(BLK)
TB2
1
2
3
4
5
1
2
3
TB1
50/200-1T 
or 
50/200-12M
(SHIELD)
(BLK)
(WHT)
 
Figure 2-6 Distributor MB-1000 
 
 
Distribution Box (Type: MB-1000, Code No.: 000-040-809) 
Name Type 
Code 
No. 
Qty 
Remarks 
Distribution 
Box 
MB-1000 000-040-805 
Cable w/8P connector supplied for 
connection to network sounder 
Crimp-on Lug 
FV1.25-3 Red  000-538-113 
 
Cord Lock 
NC-1 
000-516-650 
For use with separate transducer 
 
Fabrication of transducer cable 
Fabricate the transducer cable as illustrated below to connect it to the Distribution Box. 
Crimp-on lug
FV1.25-3, Red
Clamp here.
Tape
Vinyl Sheath
Vinyl Tube
Shield
 
Figure 2-7 Fabrication of transducer cable