Hitachi SJ700 Manuel D’Utilisation

Page de 40
Induction motor & permanent magnetic motor control
with one inverter
 (PM motor control : ordering production)
Details of enhancement
 (Comparison between SJ700-2 and SJ700D-3)
6
The SJ700D series 
inverter can drive both 
induction motors (IM)and 
permanent magnetic 
motors (PM).
IM
PM
PM
+Dedicated Controller
IM+Inverter
The Hitachi SJ700D-3 series 
succeed the SJ700-2 series with the additional 
and enhanced features
No.
item
Enhanced function, added parameters, etc.
Remarks
1
Model
SJ700D-004 to 550LFF3/LFEF3/LFUF3 SJ700D-007 to 1320HFF3/HFEF3/1500HFUF3
2
Added
function
Constant torque/ 
Variable torque   
(CT/VT) selection
Constant torque / Variable
torque mode selectable
(b049)
Newly added parameter b049 to switch between 
Constant torque mode and Variable torque mode.
In case of driving light load application, you can 
choose one power size smaller inverter or one 
frame size smaller inverter.
3
PM motor control
 [ordering production]
Control mode (A044) 
PM motor control (06) is added to the selection in A044 
PM motor control is only available in Variable torque 
mode.  
(note) The model supporting PM motor control is 
ordering production. 
4
PM motor control 
parameters (H101~H134) 
Parameters related to PM motor control are newly added 
(same as WJ200 series)
5
Automatic return 
to the initial display 
Automatic return
to the initial display (b164)
Without operating for 10 minutes, 
the display returns to the initial display automatically. 
6
Data read and 
write
Data Read/Write selection
 (b166)
Selection of enabling or disabling data Read / Write from the 
copy unit WOP for parameter setting protection and security
7
Inverter mode
Inverter mode monitor
 (d060)
Displays currently selected inverter mode, IM motor 
(induction motor) or PM motor mode.(IM mode or PM mode.) 
8
Phase loss 
protection
Phase loss output 
protection (b141,b142)
The inverter detects motor output phase loss
9
Improvement
function
EzSQ
Improvement
Parallel processing of 5 tasks
10
EzSQ starting trigger terminal: changed from FW terminal to 
PRG terminal which can be assigned any of input terminals.
11
Additional function
Always running mode is added to 
selection of starting method for EzSQ. 
12
Command to store changed data into EEPROM (eepwrt command)
13
Command to obtain clock data from WOP (rtcset command)
14
Part of EzSQ program variables (P129 (U29) to P131 (U31)) 
are automatically stored at power down (only when A017 is 
other than 00)
15
WOP operator 
[Option] 
Full compatibility with the copy unit WOP(5 line display)
16
Real time clock function is available. 
17
RS485 
Communication speed 
is improved. 
2400/4800/9600/19.2k/38.4k/57.6k/76.8k/115.2k bps 
18
Modbus RTU
Maximum data length is expanded. 
03h (Read holding register) 10h (Write in holding resisters) 
4 registers (8 byte) to 16 registers (32 byte)
19
Command to write into/read from multiple holding registers 
is added (17h: Write/Read multiple holding registers)
Read and Write 16 registers (32 byte)
20
Broadcast communication function is added. 
21
EEPROM storing mode is added. 
22
Initializing 
Initializing method 
Parameter setting (b180=01) triggers initialization
Initialization method of SJ700-2  is also valid.
23
Initializing of EzSQ 
Parameter b084 range is expanded. 
24
Initial value 
b037=00 (Full access) 
25
Selection of
initial display
Selection of initial display is expanded
(all monitoring parameters, frequency command F001 (WOP monitor B)
26
Others
Warnings
Warnings are organized. 
47 warnings to 31 warnings
27
Run command in
case of warnings
At occurrence of warning, the inverter does not accept Run command.
2