3M WSMONITOR3 Manuel D’Utilisation

Page de 11
9
Operation
 
Place a wrist band on your wrist and plug the coiled cord banana plug into 
the monitor’s banana jack. The monitor will display a green light when a 
functional wrist strap with good skin contact is connected to the unit.
 
The unit will sound an alarm and display a red light if the wrist strap becomes 
defective or if the person is not in contact with the band.
 
Unplug the wrist strap coiled cord from the unit to stop the alarm. 
 
Monitor will alarm if the continuity from the monitor to the mat to ground is 
lost. 
Calibration / Verification
Adjustments or calibration are not required for the 3M
 Constant Monitors 
WSMONITOR1, WSMONITOR2, WSMONITOR3. The TMTOOL unit 
simulates a correctly functional person and wrist strap (Accept) and an open 
circuit (Reject). The TMTOOL also simulates high resistance for verification of 
your work surface.