UNDER THE CABINET INSTALLATION – REAR VENT 
 
 
Preparation before Installation 
 
NOTE:  TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE   
VENT OPENING. 
-  Decide the location of the venting pipe from the hood to the outside.  Refer to Figure 6. 
 
-  A straight, short venting run will allow the hood to perform more efficiently. 
  -  Try to avoid as many transitions, elbows, and long run as possible.  This may reduce 
the performance of the hood. 
-  Temporarily wire the hood to test for proper operation before installing. 
-  Peel protective film off the hood (if any).  
-  For installing under the cabinet with recessed bottom, attach 4-inch wide wood filler 
strips (not included) on each side.  Refer to Figure 7. 
-  Measure and create access opening for electrical wires under the cabinet or access 
opening for the electrical wires at the rear of the hood. 
-  Remove the screws on the vent cover (rear) and cut along the line of the inner vent 
cover (rear) opening.  Refer to Figure 8. 
-  Cut the vent cover (rear) opening and reverse to the other side.  Refer to Figure 9.  
Reattach the vent cover (rear). 
 
        
 
 
 
 
 
 
 
 
 
                              
Figure 6                                                             Figure 7 
 
 
 
 
 Inner Vent 
Reversed 
                                                    Cover (Rear)                                                       Vent Cover                            
                                                                                                                                (Rear) 
 
 
 
 
                                   Figure 8                                                              Figure 9                                          
                                    
Hood Installation 
 
CAUTION: If required to move the cooking range to install the hood, turn off the power on an 
electric range at the main electrical box.  SHUT OFF THE GAS BEFORE MOVING A GAS 
RANGE.