U-Line 2175RC Manuel D’Utilisation

Page de 24
U-Line 2000 Series Maintenance
13
1
2
1
7 Maintenance
Lightbulb Replacement
To replace the lightbulb in your U-Line unit:
1. Find the light located at the top of the unit. Grasp the edges of 
the light housing lens (1) opposite the exposed tab and gently 
push the lens toward the tab (2).
2. Pull the edge of the lens down (1) and swing it out of the light 
housing.
Removing and Installing Grille
WARNING
Disconnect electric power to the unit before removing 
the grille.
WARNING
DO NOT touch the condenser fins(4). The condenser 
fins are SHARP and can be easily damaged.
Removing the grille.
1. Disconnect power to the unit.
2. Remove control knob (6) if equipped.
3. Loosen the two screws (1). Some models may have only one 
screw in the center.
4. Remove grille (2) and grille cap (if equipped)(3) from unit.
Installing the grille:
1. For 15 and 29 models make sure grille cap (3) is behind grille in 
slots (2) provided in grille before attaching grille to unit.
2. For 75 models place the hook-hinge located on the rear bottom 
side of the grille (2) onto the front lip of the unit base. Swing the 
grille up into position. 
3. Align cabinet and grill holes and secure, but do not overtighten 
grille screws (1).
4. Install control knob (6) if equipped.
5. Reconnect power to the unit.
IMPORTANT
IMPORTANT
ALWAYS use a genuine U-Line replacement 120V 10 watt 
bulb (Part Number 31317) in the light housing. Use of any 
other bulb within the housing will produce excessive heat, 
causing damage to the light housing and cabinet interior, 
and will compromise the precise temperature control of 
the unit.
1. Replace the lens by first inserting the tab side back into the 
housing at a slight angle. 
2. While gently pushing the lens towards the tab end, push the free 
end into the housing, and release when you hear a snap.
For Models with adjustable leveling feet:
1. Use a level to check the levelness of the unit from front to back 
and from side to side. Place the level along top edge and side 
edge as shown (1).
2. If the unit is not level, rotate the adjustable leveling legs to raise 
or lower each corner of the unit (5) as necessary.
3. Check levelness after each adjustment and repeat the previous 
steps until the unit is level.
Leveling
IMPORTANT
IMPORTANT
Unit must be level, for proper door and ice maker (if 
equipped) operation. 
Typical Model Shown
4
1
2
5