Samsung RF267AEBP Manuel D’Utilisation

Page de 118
80
TROUBLESHOOTING
4-2-13. If Water is not supplied
☞ Checking method of Valve resistance (Must
power off for checking)
Resistance can be changed by input voltage.
CN70#1 (Red) 
↔ CN73#5 (White-black)
-  resistance value ; 388(1.6k)Ohm 
± 7%)
** 0
Ω: Short trouble / ∞Ω: Open trouble
Start
Is the confirming sound of
the valve operation heard
when dispenser switch
pushed?
Is the valve unit normal?
Is the voltage of PCB IC01
MICOM #15 changed 0V~5V
according to switch On/Off?
Does Main PCB IC73 #3
have about 5V input?
Does Main PCB IC73 #14
have about 0.7V output?
Is the contact point of main
PCB RELAY RY7A normal?
MAIN PCB normal
-- Need to check the other parts
① Check the wire between water valve ↔
MAIN PCB
② Ice water valve itself has trouble or bad
contact of connector
③ Check the connection hose
④ Check the operation between Panel PCB
and MAIN PCB for Communication.
Normal(Check Ice
water valve hose)
Replace Valve
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB
1) Check the dispensing
lever
2) Check switch unit/ wiring
connection
3) Replace PCB
typical PCB Ground CN1#3(Black)
☞ Checking method of voltage
Based on PCB typical Ground CN1#3(Black)
1) Check voltage of IC73# (same voltage as
IC01#64)
- Water valve operating (about 5V
±0.5V)
Based on PCB typical Ground CN1#3(Black)
2)  IC73 #14 voltage
- Water valve operating (about 0.7V
±0.5V)
3) Check the voltage of Water Valve operating
(AC voltage)
=> For checking the Relay RY7A operating.
CN70#1(Red) 
↔ CN73#5(White-black)
- ICE Water valve waiting (about AC 0V)
- ICE Water valve operating (about AC 110(230)V 
± 20%)
AW-SEM Transform(RF267,2#3957D8  
2009.8.20 4:55 PM  
페이지80    in