Fujitsu MAN3735 Manuel D’Utilisation

Page de 302
C141-E124-01EN
5 - 11
5.1.3
Sense data additional information
Bytes 18 to 47 of sense data are defined as a Fujitsu unique field, and indicate the additional
information which is explained below.
(1)
IDD SCSI ID
This field shows the SCSI ID of the very IDD which generated the sense data.
(2)
CDB operation code
This field indicates the operation code (the value in the first byte of the CDB) of the command
where the error occurred.  When sense data are generated without relation to the INIT issuing a
command, this field shows zero.
(3)
Detailed information
The information displayed in bytes 20 to 47 of sense data is information defined by Fujitsu for the
specific product for the purpose of analyzing trouble, and the contents of this information are not
made public.  However, the user should present this information to the persons in charge at Fujitsu
as troubleshooting and repair information collected in error logging (shown in Section 5.3.3) of all
the bytes in sense data, including this field.