Everpure EV9613-06 Fascicule

Page de 1
MH Cartridge   Part No. EV9613-01 (1-pack) 
Part No. EV9613-06 (6-pack)
MH
2
 Cartridge   Part No. EV9613-21 (1-pack) 
Part No. EV9613-26 (6-pack)
FEATURES
  •  Finely polishes treated water to premium quality. 
  •  Reduces chlorine taste and odor. 
  •   Reduces dirt, rust, asbestos fibers, and other particulates 
including oxidized iron, manganese, and sulfides.
  •   Reduces parasitic protozoan cysts such as Giardia, Entamoeba, 
and Cryptosporidium.
  •  Reduces common earthy, moldy, fishy tastes and odors
  •   Inhibits limescale build-up in ice machines – As tested by 
Everpure.
  •   MH
2
 cartridges are treated with bacteriostat to effectively reduce the 
growth of bacteria on the filter media. Not Performance Tested or 
Certified by NSF.
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*
This system has been tested according to NSF/ANSI 42 and 53 for the 
reduction of the substances listed below. The concentration of the 
indicated substances in water entering the system was reduced to 
a concentration less than or equal to the permissible limit for water 
leaving the system, as specified in NSF/ANSI 42 and 53.
Substance
Influent Challenge 
Concentration 
Max. Permissable Product 
Water Concentration 
Reduction 
Requirements
Minimum 
Reduction
Average 
Reduction
Standard 42—Aesthetic Effects
Chlorine
2.0 mg/L ± 10%
≥ 50%
87.8%
Particulate, 
Class I 
particles 0.5 
to <1 µm
at least 10,000 
particles/mL
≥ 85%
99.2%
Standard 53—Health Effects
Turbidity
11 ± 1 NTU
0.5 NTU
95.4%
97.2%
Asbestos 
10
7
 to 10
8
 fibers/L > 10 
micrometers in length
99%
99.87%
99.87%
Cyst 
Minimum 50,000/L
99.95%
99.99%
99.99%
*  Tested using flow rate = 1.67 gpm; pressure = 60 psig; pH = 7.5 ± 1; 
temp. = 20° ± 3°C
† NTU = Nephelometric Turbidity Units
GENERAL INSTALLATION/OPERATION/MAINTENANCE 
REQUIREMENTS
  •  Install vertically with cartridge hanging down
  •  Use minimum length of tubing possible
  •  Flush to drain for 5 minutes at full flow
  •   Replace cartridges when capacity is reached or when flow 
becomes too slow, but at least annually.
OPERATING SPECIFICATIONS
  •  Pressure requirement: 10-125 psi (0.7-8.6 bar), non-shock
  •  Temperature: 35-100° F (2-38° C)
NSF Listed Systems
Max. Flow Rate
Capacity
Space Requirements*
QC7I Single - MH
1.67 gpm (6.3 lpm)
9,000 gal (34,050 L)
29" H x 5
1
2
" W x 5" D
QC7I Single - MH
2
1.67 gpm (6.3 lpm)
9,000 gal (34,050 L)
29" H x 5
1
2
" W x 5" D
QC7I Twin - MH
3.3 gpm (12.6 lpm)
18,000 gal (68,100 L)
25" H x 11" W x 5" D
QC7I Twin - MH
2
3.3 gpm (12.6 lpm)
18,000 gal (68,100 L)
25" H x 11" W x 5" D
QC7I Triple - MH
5.0 gpm (18.9 lpm)
27,000 gal (102,150 L)
25" H x 15" W x 5" D
QC7I Triple - MH
2
5.0 gpm (18.9 lpm)
27,000 gal (102,150 L)
25" H x 15" W x 5" D
QC7I Quad - MH
6.6 gpm (25.3 lpm)
36,000 gal (136,200 L)
29" H x 24" W x 5" D
QC7I Quad - MH
2
6.6 gpm (25.3 lpm)
36,000 gal (136,200 L)
29" H x 24" W x 5" D
* Includes 2
1
2
” clearance under unit for cartridge change 
SPECIAL NOTICES
  •   Installation instructions, parts and service availability, and 
standard warranty are included with the product when shipped.
  •   This drinking water system must be maintained according to 
manufacturer’s instructions, including replacement of filter 
cartridges.
  •   Do not use with water that is microbiologically unsafe, or of 
unknown quality without adequate disinfection before or after 
the system. Systems certified for cyst reduction may be used on 
disinfected waters that may contain filterable cysts.
  •   The contaminants or other substances removed or reduced by 
this water treatment system are not necessarily in your water.
  •  Check for compliance with state and local laws and regulations.
  •   Tested under standard laboratory conditions as specified above.  
Actual performance may vary depending on influent water 
conditions.
  •   To determine NSF Model Name, combine HEAD NAME + 
CARTRIDGE NAME. Refer to www.nsf.org to verify certification.
MH AND MH
2
 WATER FILTERS
©2005 Everpure, LLC 
EV7013-18B   OC05
Buyer 
Seller 
Date
WATER TREATMENT PRODUCTS
1040 Muirfield Drive • Hanover Park, IL 60133 • 630.307.3000 • FAX 630.307.3030
PERFORMANCE 
DATA SHEET
System Tested and Certified by NSF International against 
NSF/ANSI Standards 42 and 53 for the reduction of:
Standard No. 42 —
Aesthetic Effects
Chemical Reduction
Taste and Odor
Chlorine
Mechanical Filtration
Particulate Class I: 99.2% reduction of particles  
one-half micron and larger in size
Standard No. 53 —
Health Effects
Mechanical Filtration
Turbidity
Cyst
Asbestos