For vented installations, you will also need: 
1 wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will also 
need:
Recirculation Kit Part Number W10272065 for non-vented 
(recirculating) installations only. See “Assistance or Service” 
section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs 
installed
8 vertical supports
2  glass mounting brackets
Glass mantle
Mounting template
Upper horizontal support
Horizontal support
4 plastic brackets (for lower chimney fixings)
2 plastic brackets (for upper chimney fixings)
68 - 4 x 8 mm screws
4 - 3.5 x 9.5 mm glass mantle mounting screws
4 - 5 x 45 mm screws
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial rating 
plate is located behind the left filter on the rear wall of the vent 
hood.
Canopy hood location should be away from strong draft areas, 
such as windows, doors and strong heating vents. 
Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical 
Requirements” section.
Because of the size and weight of this island hood, the chimney 
support must be securely attached to the ceiling.
For plaster or drywall ceilings, the chimney support must be 
attached to joists. If this is not possible, you must build a 
support structure behind the plaster or drywall. The support 
structure must be able to support 80 lbs (36.6 kg).
The range hood is factory set for venting through the roof or wall.
For non-vented (recirculating) Installation see “Non-vented 
(recirculating) Installations” in “Install Range Hood” section. 
Recirculation Kit Part Number W10272065 is available from your 
dealer or an authorized parts distributor. 
All openings in ceiling and wall where range hood will be installed 
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local 
codes.
Product Dimensions
*Vented installations only
**Non-vented (recirculating) installations only
Installation Clearances
IMPORTANT:
Minimum distance “C”: 24" (61.0 cm) from electric cooking 
surface.
Minimum distance “C”: 27" (68.6 cm) from gas cooking 
surfaces. 
Suggested maximum distance “C”: 36" (91.4 cm)
For vented installations, the chimneys can be adjusted for 
ceilings between 8' (2.4 m) and 9' 11" (3.0 m).
For non-vented (recirculating) installations, the chimneys can 
be adjusted for ceilings between 8' (2.4 m) and 10’ 4" (3.1 m).
A. Ceiling height
B. Hood height from ceiling to bottom of the 
range hood: A-C-D=B
C. Hood height: 24" (61.0 cm) min. from 
electric cooking surface, 30" (76.2 cm) 
min. from gas cooking surface, suggested 
36" (91.4 cm) max
D. Countertop height
36" - 42" (91.4 cm to 106.7 cm)
25¼" (64.0 cm)
13
³⁄₈
" (33.8 cm)
15" (38.0 cm)
*35
³⁄₁₆
" (99.5 cm) min.
   53
³⁄₁₆
" (152.8 cm) max.
**35
³⁄₁₆
" (107.0 cm) min.
   56
³⁄₁₆
" (158.0 cm) max.
1½" (4.0 cm)