Cornelius CCM0830 Manuel D’Utilisation

Page de 129
 
 
 Troubleshooting Trees 
Page C3 
 
Machine Does Not Run 
 
 
 
Check for correct 
power supply to the 
machine 
YES 
NOT OK 
NO 
OK 
 
Is the selector 
switch set to 
ICE
 
Check High 
Pressure Safety 
Control 
 
Check High 
Temperature Safety 
Control 
OK 
 
Check Bin Control 
for proper 
adjustment, see 
page F9 
 
 
Is this a Remote 
unit? 
 
Is the Liquid line 
Solenoid energized 
and open? 
OK 
OK 
GOOD 
TRIPPED
OPEN 
BAD 
NO
NOT OK
 
OK
 
Adjust as 
required or 
replace if 
defective 
 
Replace or 
identify reason 
for being open. 
 
Reset and 
identify reason 
for high head 
pressure 
 
 
Correct field 
wiring deficiency 
 
 
Set selector 
Switch to the 
ICE position 
 
Selector Switch 
could be 
defective, see 
page F1 
 
 
Find reason for 
non-activity or 
replace if 
defective