Cornelius DF250 Fascicule

Page de 1
Ice Diverter ED/DF Dispensers Installation Instructions
© 2004-2005, IMI Cornelius Inc.
- 1 -
Publication Number: 92303INS
INSTALLATION INSTRUCTIONS
ICE DIVERTER ED/DF DISPENSERS K
IT
 P/N 02394
NOTE:  For dispensing Scotsman NME654, NME954 and NME 1254 “Nugget” style ice and 
Cornelius WCC500 and WCC700 “Chunklet” style ice cubes.
1.
Disconnect power to dispenser.
2.
Remove upper front panel/merchandiser from dispenser.
3.
Remove ice chute portion and gate restrictor.
4.
Install ice diverter as shown (see FIGURE 1) and reinstall the gate restrictor removed in previous 
step. Gate restrictor should be installed in ‘front’ of ice diverter. It is critical the opening be set a 
minimum of 1 ½” (see FIGURE 2).
FIGURE 1. Exploded View of Ice Diverter Installation
5.
Remove screws securing white reflector panel and gain access to electrical box. Locate timer board 
and reset agitation timer to 2 seconds ‘ON’ and 3 hours ‘OFF’ (see FIGURE 3).
6.
Re-install front panel and plug unit back into outlet.
Unit should now be ready to dispense ice for customer use.
FIGURE 2. Gate Restrictor with 1 ½” Opening
FIGURE 3. Timer Board Settings Reset
STORAGE 
HOPPER
GATE 
MOUNTING 
PLATE
ICE DIVERTER 
P/N 15484
ICE CHUTE
FLANGE EXTENDS 
INTO STORAGE 
HOPPER THROUGH 
GATE OPENING
APPLY RTV TO THIS 
SURFACE TO SEAL TO 
HOPPER GATE 
MOUNTING PLATE
GASKET
FLAT WASHER
10-32  NUT
Revision Date: June 2, 2005
 www.cornelius.com
Revision: C