SEQUENCE OF OPERATIONS 
 
1130-000-A / 208V / SINGLE PHASE 
1131-000-A / 240V / SINGLE PHASE 
1132-000-A / 208V / THREE PHASE 
1133-000-A / 240V / THREE PHASE 
 
 
POWER SUPPLY 
Electrical power to be supplied to the oven by a three-conductor service on single 
phase and a four-conductor service on three phase. 
 
 
Black conductor is Hot 
 
Red conductor is Hot 
 
Orange conductor is Hot  (Used on 3 phase only) 
 
Green conductor is ground. 
 
CONTROL BOX AUTO COOL DOWN  When the temperature in the control box reaches 120°F ± 3°F (48.9°F ± 1.7°C), 
the cooling fan thermostat will switch power to the cooling fans.  The thermostat 
will interrupt power to the fans when the temperature falls to 100°F ± 3°F (37°C ± 
1.7°C). 
 
MAIN FAN CIRCUIT 
Power is permanently supplied through the 10A fuses, through the normally 
closed control box high limit thermostat, to the normally open main fan switch.  
Power is also supplied to the normally open cooling fan thermostat.  Closing the 
main fan switch supplies 208/240 VAC to the main fan motor, the cooling fan 
motor, to the primary of the temperature display transformer and to the heat and 
conveyor circuits. 
 
HEATER CIRCUIT 
Closing the fan switch supplies 208/240 VAC, through the normally open air 
pressure switch (closed by air pressure from the main fan) through the normally 
closed oven cavity hi-limit thermostat, to the electronic temperature control.  The 
1K ohm temperature pot is adjusted to desired temperature.  The thermocouple 
will provide varying millivolts to the temperature controller.  The temperature 
control then supplies 208/240 VAC to the coil of the contactor at intermittent 
intervals to maintain the desired temperature.  The heat lamp is energized with 
the contactor. 
CONVEYOR DRIVE 
Closing the on/off switch supplies 120 VAC to the motor control board.  AC volts 
are converted to DC volts and are supplied to the conveyor motor at terminals A+ 
and A-. 
 
 
Adjustment of the speed control potentiometer will change resistance at terminals 
P1 and P2 varying the DC voltage to the motor.  The speed of the conveyor 
motor will increase or decrease as the DC voltage from the board increases or 
decreases respectively. 
 
NOTE: 
The conveyor control uses a sensor and magnet, mounted on the conveyor 
motor that senses the motor speed.  Any change in motor load (±RPM) is 
detected by the sensor and the voltage to the motor is adjusted accordingly. 
 
Temperature Display 
Closing the switch supplies 120 VAC to the primary of the temperature display 
transformer.  The secondary of this transformer supplies 12 VAC to the 
temperature display.  The thermocouple supplies D.C. millivolts to the 
temperature display.  The display converts this millivolt reading to a temperature 
reading.