Jenn-Air JGS9900BD Manuel D’Utilisation

Page de 73
Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing, 
unless testing requires power and/or gas. 
 
© 2006 Maytag Services
 16026923 
19 
Electronic Oven Control (EOC) III Testing Procedures 
Warm
Drawer
ATM PADS
 
ELECTRONIC OVEN CONTROL (EOC) III TESTING/PROGRAMMING PROCEDURES 
Feature 
Access Procedure 
Modification Procedure 
Control Reset 
Resets control to factory default 
values. 
Press the Setup pad, then press the right 
ATM
 pad until SERVICE displays.  Press 
the left ATM pad to select SERVICE menu 
options. 
Press and hold the Back and Enter pads for 5 
seconds to enter SERVICE menu options.  Press 
the right ATM pad to scroll to CONTROL RESET.  
Press the left ATM pad to select CONTROL 
RESET, then press the left ATM pad again to reset 
the control logic.  Press Setup to exit. 
Oven Temperature Adjustment 
Determines oven cavity offset 
temperature (range from -35° F to 
+35° F, or -21° C to +21° C). 
Press the Setup pad, then press the right 
ATM
 pad until TEMP ADJUST displays.  
Press the left ATM pad to select oven 
TEMP ADJUSTMENT settings. 
Enter the offset temperature setting desired using 
the digits pads.  Press the right ATM pad for + 
temperature adjustment, or the left ATM pad for – 
temperature adjustment.  Press 0 to reset control 
back to no temperature adjustment.  Wait 3 
seconds for the control to accept the request.  
Press Setup to exit. 
Sabbath Mode 
Based on the Jewish guidelines 
for Sabbath/Holiday 
requirements. 
Press the Setup pad, then press the right 
ATM
 pad until SABBATH displays.  Press 
the left ATM pad to select SABBATH 
settings. 
Press the left ATM pad to select Manual Sabbath 
mode, or the right ATM pad to select Auto Sabbath 
mode.  Press the left ATM pad to turn on Sabbath 
mode, or the right ATM pad to turn off Sabbath 
mode.  Press Setup to exit. 
Time Options 
Determines control time, day of 
week, 12/24 hour clock. 
Press the Setup pad, then the left ATM 
pad to select TIME OPTIONS. 
Press the right ATM pad to scroll to the desired 
function to modify. 
Time Set 
Determines time of day to display 
on control. 
Press the Setup pad, then the left ATM 
pad, then the left ATM pad again to set the 
time of day clock. 
Enter the correct time using the digits pads and 
press Enter.  Press the left ATM pad to select AM 
or the right ATM pad to select PM. Press Setup to 
exit. 
Day of Week 
Determines day of week (Monday 
thru Sunday) to display on 
control. 
Press the Setup pad, then the left ATM 
pad, then press the right ATM pad until 
DAY displays.  Press the left ATM pad to 
set the day of the week. 
Press the right ATM pad until the correct day 
displays, then press the left ATM pad to select.  
Press Setup to exit. 
12/24-Hour Clock Display 
Determines 12-hour or 24-hour 
clock display on control. 
Press the Setup pad, then the left ATM 
pad, then press the right ATM pad until 
12/24HR displays.  Press the left ATM pad 
to select 12/24 HR clock. 
Press the left ATM pad to select 12-hour clock, or 
the right ATM pad to select 24-hour clock.  Press 
Setup
 to exit. 
Clock & Day Display Disable 
Determines if time of day and day 
of week will display on control. 
Press the Setup pad, then press the right 
ATM
 pad until DISABLE displays.  Press 
the left ATM pad to select DISABLE 
settings. 
Press the left ATM pad to select TIME, or the right 
ATM
 pad to scroll to DAY, press the left ATM pad.  
Press the left ATM pad to enable display or the right 
ATM
 pad to disable display.  Press Setup to exit. 
Language Display 
Determines language display on 
control (English, French, 
Spanish). 
Press the Setup pad, then press the right 
ATM
 pad until LANGUAGE displays.  
Press the left ATM pad to set LANGUAGE 
settings. 
Press the right ATM pad until the desired language 
displays (English, French, Spanish). Press the left 
ATM
 pad.  Press Setup to exit. 
C/F (Celsius/Fahrenheit) Display 
Determines temperature display on 
control (C or F). 
Press the Setup pad, then press the right 
ATM
 pad until C/F displays.  Press the left 
ATM
 pad to select C/F settings. 
Press the left ATM pad to select Celsius or the right 
ATM
 pad to select Fahrenheit.  Press Setup to exit. 
Auto Convection 
When enabled, reduces the 
Convection Bake and Pastry 
temperatures by 25° F (-3.9° C). 
Press the Setup pad, then press the right 
ATM
 pad until AUTO CONVECT displays.  
Press the left ATM pad to select AUTO 
CONVECT settings. 
Press the left ATM pad to turn on auto convect, or 
the right ATM pad to turn off auto convect.  Press 
Setup
 to exit. 
208/240 V Setting 
Determines range operating 
voltage (208 or 240 VAC). 
Press the Setup pad, then press the right 
ATM
 pad until 208/240 displays.  Press the 
left ATM pad to select 208/240 V settings. 
Press the left ATM pad to select 208 VAC, or the 
right ATM pad to select 240 VAC.  Press Setup to 
exit.