PAGE 20 —GB2000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV. #1 (02/25/14) 
LAMP ADAPTER PLATE MOUNTING INSTALLATION
1.  Remove the adapter plate kit hardware from its 
container.
2.  Before proceeding make sure the light tower mast is 
in the stow position (down) and the cradle lock/release 
pin has been inserted and the mast is locked.
3.  Attach the lamp adapter plate to the T-Bar as shown 
in Figure 7. Align adapter plate so that adapter spacer 
notch fits over screw on T-Bar. Please pay close 
attention to the orientation of the 2 support brackets. 
4.  Mount the flat end of both support brackets flush 
against the T-Bar with the 
low  end of each bracket 
facing inward toward the mast. The 
raised end of each 
bracket should be facing outward.
 NOTICE
Please pay close attention to the orientation of the 2 
support brackets. Each bracket has a high and low side. 
The low side of the bracket should be facing inwards 
towards the mast.
SETUP
5.  Next, insert a bolt (4) and flat washer (4) thru the 
mounting holes on the adapter plate as shown in Figure 
7. Again, pay close attention on which set of holes to 
insert the bolt thru. 
Bolt number 2 must be oriented 
so that it passes between receptacles J1 and J2 on 
the T-Bar.
6.  Secure the adapter plate to the T-Bar using the supplied 
flat washer (4), lock washer (4) and nut (4). Make sure 
the adapter plate is level (use a bubble level) and both 
brackets are straight (vertical), not slanted before 
tightening