Metrologic Instruments IS3480 Manuel D’Utilisation

Page de 56
 
 
39
S
CANNER
 
AND
 
C
ABLE
 
T
ERMINATIONS
 
 
Scanner Pinout Connections
 
 
The IS3480 scanner interfaces terminate to a 10-pin modular socket.  
The serial # label indicates the interface enabled when the scanner is shipped 
from the factory. 
 
Figure 15. 
 
IS3480-47 Keyboard Wedge 
and Stand-Alone Keyboard 
IS3480-41 
RS232C and Light Pen Emulation 
Pin Function 
Pin Function 
1 Ground 
1 Ground 
RS232 Transmit Output 
RS232 Transmit Output 
RS232 Receive Input 
RS232 Receive Input 
4 PC 
Data 
4 RTS 
Output 
5 PC 
Clock 
5 CTS 
Input 
KB Clock 
DTR Input/LTPN Source 
7 PC 
+5V 
7 Reserved 
8 KB 
Data 
8 LTPN 
Data 
9 +5VDC 
9 +5VDC 
10 Shield 
Ground 
 
10 Shield 
Ground 
 
IS3480-38  
RS232 Low Speed USB 
IS3480-11 
 IBM 468X/469X 
Pin Function 
Pin Function 
1 Ground 
1 Ground 
RS232 Transmit Output 
RS232 Transmit Output 
RS232 Receive Input 
RS232 Receive Input 
4 RTS 
Output 
4 RTS 
Output 
 
5 CTS 
Input 
5 CTS 
Input 
 
6 D+ 
6 DTR 
Input 
7 V_USB 
7 IBM 
B-Transmit 
8 D- 
8 IBM 
A+ 
Receive 
9 +5VDC 
9 +5VDC 
10 Shield 
Ground 
 
10 Shield 
Ground 
 
Continued on next page.