Metrologic Instruments MS9590i Manuel D’Utilisation

Page de 48
 
 
18 
I
NDICATORS
 
 
Visual 
 
Each MS9590i series scanner has three 
LED indicators (blue, white, and yellow) 
located on the head of the scanner.  
When the scanner is in operation, the 
flashing, or stationary activity of the 
LEDs indicates the status of the scanner 
and the current scan.  
 
Figure 18.  LED Configuration
 
All LEDs are Off 
The LEDs will not be illuminated if the scanner is not receiving power from the 
host or transformer. 
 
The scanner is in manual activation mode.   
 
 
Steady Yellow 
The scanner is in automatic scanning mode. 
 
 
Steady Blue 
When the laser is active, the blue LED is illuminated.  The blue LED will remain 
illuminated until the laser is deactivated (default mode only). 
 
 
Steady Blue and Single White Flash 
When the scanner successfully reads a bar code, the white LED will flash and 
the scanner will beep once.   
 
 
After a successful scan, the scanner transmits the data to the host 
device.  Some communication modes require that the host inform the 
scanner when data is ready to be received.  If the host is not ready to 
accept the information, the scanner's white LED will remain on until the 
data can be transmitted. 
 
 
Alternating Flashing of Blue and White 
During Operation 
This indicates the scanner is in configuration mode.