Dialogic SS7G22 Manuel D’Utilisation

Page de 91
66
Chapter 10 Working Inside the Product
Figure 24. Cable Tie Securing SS7 Signaling Board to Card Keep Frame
CT Bus Cable Notes
Note: When the CT Bus cable is installed, it is important that the two end connectors must be 
connected to boards. To achieve this consider the following: 
For single board systems, the CT Bus cable cannot be connected. For systems delivered as “single 
board”, the cable is stowed in clips fastened to the underside of the Top Cover. 
If adding a second board to a system, the CT Bus cable should be taken from the clips and connected to 
the two boards. 
For “two board” systems, the two end connectors of the CT Bus cable must be used, and only the center 
connector may be left disconnected. 
10.6
Replacing the Back-up Battery
A lithium battery on the Server Board provides power to maintain date and time settings in the absence of 
main AC or DC power. When the battery starts to weaken, it loses voltage, and the date and time settings 
may be wrong. The battery may be replaced by one labeled with Manufacturer and Part Number information 
that is identical to that marked on the original battery, or contact your customer service representative for 
advice on approved equivalent devices. 
Cable Tie
WARNING 
Danger of explosion if battery is incorrectly replaced. Replace only with the same or 
equivalent type recommended by the equipment manufacturer. Discard used batteries 
according to the manufacturer's instructions. 
ADVARSEL! 
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med 
batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.