Scanner Pinout Connections
The MS7320 scanner interfaces terminate to 10-pin modular jacks located on the
back of the unit. The serial number label indicates the model number of the
scanner.
Figure 31: Scanner Interface Ports
MS732x-13 OCIA
MS732x-13 IBM 46xx
Pin
Function
Pin
Function
1 Ground
1 Ground
2 NC
2 RS232 Transmit Output
3 NC
3 RS232 Receive Input
4 RDAT A
4 RTS Output
5 RDAT A Return
5 CTS Input
6 Clock in
6 DT R
7 Clock out
7 IBM B- (D-)
8 Clock in Return/
Clock out Rtrn
8 IBM A+ (D+)
9 + 5VDC
9 + 5V IN
10 Shield Ground