Metrologic Instruments MS7320 Manuel D’Utilisation

Page de 64
 
 
46 
S
CANNER AND 
C
ABLE 
T
ERMINATIONS
  
   
Scanner Pinout Connections 
 
The MS7320 scanner interfaces terminate to 10-pin modular jacks located on the 
back of the unit.  The serial number label indicates the model number of the 
scanner.  
 
 
 
Figure 31: Scanner Interface Ports 
 
 
 
 
MS732x-13 OCIA 
 
MS732x-13 IBM 46xx 
Pin 
Function  
Pin
Function 
1 Ground 
 
1 Ground 
2 NC 
 
2 RS232  Transmit Output 
3 NC 
 
3 RS232  Receive Input 
4 RDAT A
 
 
4  RTS Output  
5 RDAT A Return
 
 
5  CTS Input  
6 Clock  in
 
 
6 DT R 
7  Clock out 
 
7  IBM B- (D-) 
8  Clock in Return/ 
Clock out Rtrn 
 
 
8  IBM A+ (D+) 
9 + 5VDC 
 
9 + 5V IN 
10 Shield  Ground 
 
10 NC