Fujitsu B120 Manuel D’Utilisation

Page de 68
Troubleshooting and tips
Drives "dead" at system boot
42
A26361-K646-Z102-1-7619
7.10 Drives "dead" at system boot
SCSI drives are reported as "dead" at system boot. This error message may occur when the server
has a disk array controller.
SCSI cabling incorrect
Ê 
Make sure the SCSI cable connection and the SCSI channel assignment still correspond to the
original state.
The Disk Array Controller configuration is incorrect
Ê 
Check and correct the settings for the drives with the disk array controller utility
DACCF
.
Further information is provided in the manual on the disk array controller.
7.11 Added drive defective
An added SCSI drive is reported as defective This error message may occur when the server has a
disk array controller.
Disk Array Controller is not configured for this hard disk drive
The drive was probably installed with the system switched off.
Ê 
Reconfigure the disk array controller for the hard disk drive. Information is contained in the
documentation on the disk array controller.
or
Ê 
Re-install the drive while the system is switched on.
If the hard disk drive continues to be shown as defective, then replace it (see "
subsystem
").
7.12 Error messages on the screen
The meaning of the error message is contained in the manual on
BIOS setup
and in the
documentation on the boards and programs used.