Leviton LTB15 Fascicule

Page de 2
Single Pole (One location) or 3-Way (Multi-location)
Electronic Countdown Timer Switch 
Cat. No. LTB15, LTB30, LTB60, LTB02, LTB12 Lighted
20A Resistive/Inductive, 1800W Incandescent, 1HP
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult an electrician.
•  Leviton electronic countdown timer switches are not compatible with standard 3-way or 4-way switches. They must be used with compatible  
Vizia +
®
ON/OFF remote switches.
•  Recommended minimum wall box depth is 2-1/2”.
WARNINGS AND CAUTIONS:
Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•  Use only one (1) Leviton electronic countdown timer switch in a multi-location circuit with up to 9 coordinating remote switches
without LEDs or up to 4 matching remote switches with LEDs.
•  Maximum wire length from timer switch to all installed remote switches cannot exceed 300 ft (90 m).
•  Use this device only with
copper or copper clad wire only.
IMPORTANT: For 3-Way applications, note that one of the screw terminals
from the old switch being removed will usually be a different color (Black)
or labeled Common. Tag that wire with electrical tape and identify as the
common (Line or Load) in both the switch wall box and remote wall box.
 TOOLS NEEDED TO INSTALL YOUR TIMER SWITCH
Slotted/Phillips Screwdriver
Electrical Tape
Pliers 
Pencil 
 
 
Cutters 
 
Ruler
WIRING TIMER SWITCH:
Connect wires per WIRING DIAGRAM as follows:
•  Green or bare copper wire in wall box to Green lead.
•  Line Hot wall box wire to Black lead.
•  Load wall box wire to Red lead.
•  Line Neutral wall box wire to White lead.
•  Timer Switch Yellow/Red lead should have Red insulation label affixed.
Proceed to Step 5.
Hot (Black)
Neutral (White)
Coordinating Remote Switch (no LED)
YL/RD 
YL/RD
RD 
WH
RD
BK
Bla c k 
BK 
WH 
White 
Line 
120VAC, 60Hz
Green 
Ground 
Green
Ground
(u n used ) 
(u n used ) 
Load 
Timer Switch
WIRING TIMER SWITCH:
Connect wires per WIRING DIAGRAM as follows:
NOTE:
The timer switch must be installed in a wall box that has a Line
Hot connection.
NOTE: Maximum wire length from timer switch to all installed remote
switches cannot exceed 300 ft (90 m).
•  Green or bare copper wire in wall box to Green lead.
•  Line Hot (common) wall box wire identified (tagged) when removing
old switch to Black lead.
•  First Traveler wall box wire to Red lead
(note wire color).
•  Remove Red insulating label from Yellow/Red lead.
•  Second Traveler wall box wire to Yellow/Red lead
(note wire color)
This traveler from the timer switch must go to the terminal screw on
the remote switch marked "YL/RD".
•  Line Neutral wall box wire to White lead.
WIRING VIZIA     COORDINATING REMOTE SWITCH:
Connect wires per WIRING DIAGRAM as follows:
NOTE:
"BK" and "RD" terminals on coordinating remote switch are
unused. Tighten both screws.
NOTE: Maximum wire length from timer switch to last remote switch
is 300 ft (90 m).
•  Green or bare copper wire in wall box to Green terminal screw.
•  Load wall box wire identified (tagged) when removing old switch to
First Traveler 
(note color as above).
•  Second Traveler wall box wire
(note color as above) to terminal
screw marked "YL/RD". This traveler from the remote switch must go
to the Yellow/Red lead of the timer switch.
•  Remove White insulating label from terminal screw marked "WH".
•  Line Neutral wall box wire to terminal screw marked "WH".
•  Proceed to Step 5.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
WARNING: 
TO AVOID FIRE SHOCK OR DEATH; TURN 
OFF POWER at circuit breaker or fuse and test that power is
off before wiring!
 
Step 1
2
4
3
1
2
4
1
5
3
Single Pole
1.
 Line (Hot)
2. Neutral
3. Ground
4. Load 
3-Way
1.
 Line or Load (see 
IMPORTANT instruction)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note 
color.
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble any of
these configurations, consult an electrician.
 
Step 2
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove this insulating label.
1
2
Black
White
Red
4
Yellow/Red
Green
3
Single Pole Wiring Application:
 
Step 4a
 
Step 4a cont'd
2
1
4
BK
RD
YL/RD
Coordinating Remote Switch
Timer Switch
5
3
1
2
Black
White
Red
4
Yellow/Red
Green
3
5
WH
3-Way Wiring with Vizia + Coordinating  Remote 
Switch (no LED) Application:
 
Step 4b
•  Make sure that the ends of the wires from the wall box are 
straight (cut if necessary).
•  Remove insulation from each wire in the wall box as shown.
•  For Single-Pole Application, go to Step 4a.
•  For 3-Way Coordinating Remote Switch (no LEDs) Application, go to Step 4b.
•  For 3-Way Matching Remote Switch (with LEDs) Application, go to Step 4c.
 
Step 3
Preparing and connecting wires:
Pull off pre-cut insulation from timer switch leads. Make sure
that the ends of the wires from the wall box are straight (cut if
necessary). Remove insulation from each wire in the wall box
as shown:
5/8" 
(1.6 cm)
Strip Gage 
(measure bare 
wire here)
Cut 
(if necessary)
 
Step 4b cont'd
Changing the color of your device:
Your device may include color options. To change color of the face,
proceed as follows:
Push in side 
at tab to release
Line up tabs and 
press in sides one  
at a time to attach
For non-standard wiring applications, refer to 
Wire Nut and Connector Size Chart
WIRE CONNECTOR / # OF COND. COMBINATION CHART
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 to 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
Timer Switch
Insulating
Label
Black
Hot (Black)
Black
Line
120 VAC, 60Hz
Neutral (White)
Red
Yellow/Red
White
White
Green
Ground
Load
PK-93796-10-00-2A
NOTE: Use check boxes when Steps are completed.
 INSTALLING YOUR TIMER SWITCH
+
MAXIMUM LOAD PER TIMER FOR MULTI-DEVICE INSTALLATIONS
Load
Single
Two Devices
More than 2 devices
Resistive Load
20A (2400W)
16A (1920W)
16A (1920W)
Incandescent Load
1800W
1800W
1800W
Inductive Load
20A
16A
16A
Motor Load
1HP
1HP
1HP
NOTE: For matching remote w/LEDs installation,