Technical Specifications 
3.2  Environmental Specifications 
Parameter 
Range 
Comments 
Ambient Operating 
Temperature 
-20 to 60
°C 
-40 to 85
°C (Optional) 
Ambient Temperature as measured from 
a 30 cm radius surrounding the center of 
the enclosure. 
Ambient Storage 
Temperature 
-40 to 85
°C 
 
Ambient Relative 
Humidity 
up to 95% 
Non-condensing, 55
°C, 6 cycles 
Vibration 1g 
(10-500Hz) 
Shock 30g 
11ms 
Table 9: Environmental Specifications 
 
3.3  Power Supply Specifications 
Power Supply 
Type 
Minimum 
Input 
Maximum 
Input 
Fuse 
Rating 
Maximum 
Power 
Consumption 
24 VDC 
9 VDC 
36 VDC 
3A (T) 
9W 
Table 10: Power Supply Specifications 
NOTES: 
•  (T) denotes a time-delay fuse 
•  For continued protection against risk of fire, replace only with same type and 
rating of fuse. 
 
3.4  Failsafe Relay Specifications 
Parameter 
Value 
Max Switching Voltage 
30VAC, 80VDC 
Rated Switching Current 
0.3A @ 30VAC 
1A @ 30VDC, 0.3A @ 80VDC 
Table 11: Failsafe Relay Specification 
NOTES: 
• Resistive 
Load. 
•  For Class-2 circuits only. 
 
Isolation 
Comments 
1500 V
rms
 
Dielectric test voltage (1 minute) between coil & contacts 
Table 12: Failsafe Relay Isolation 
 