Avaya P550R Manuel D’Utilisation

Page de 43
610-0184-095
 26
June 14, 2001
Problem:  
If you remove the Public community string from the SNMP 
Community Management, save the running config to the startup 
config and then reset the switch, the Public community string you 
removed is not deleted.
Workaround:  
Change the Public Community string to a different name.
P580/P882 Chassis Slot 2
The following problem has no workaround: 
Cajun P580/P882 switches running in Fabric 2 mode will not 
route inbound multicast traffic received by an unlicensed 80-
Series module when installed in slot 2.
Downloading the Startup Configuration File 
Problem:  
Downloading the startup configuration file produces panic messages 
in the CLI of the supervisor module and ATM Uplink module. 
Workaround:  
Ignore these messages.
Supervisor Module
80-Series 
Supervisor 
Module
The following problem has no workaround: 
To successfully synchronize two 80-Series Supervisor 
modules (M8000R-SUP), both modules must be in 48-port 
mode and in the same fabric mode.
Problem:  
Panic messages display on the CLI and on the Primary Supervisor 
LED readout after you install a second Supervisor module for 
redundancy. 
Workaround:  
Ignore these messages.