DELL N3000 Manuel D’Utilisation

Page de 1460
Configuring Link Aggregation
945
to the primary switch for handling. FDB entries learned on MLAG 
interfaces are synced between the two devices.
interface range gi1/0/1-4
channel-group 2 mode active
exit
interface range gi1/0/5-8
channel-group 3 mode active
exit
interface port-channel 2
switchport mode trunk
vpc 1
exit
interface port-channel 3
switchport mode trunk
vpc 2
exit
Switch Firmware Upgrade Procedure
MLAG supports minimally intrusive firmware upgrade of the MLAG peer 
switches. In most cases, protocols with retransmission capability, e.g., TCP, 
will experience a limited interruption of service. Network operators must 
ensure that the aggregate bandwidth in use on the MLAG can be supported 
on a single MLAG peer.
Use the show vpc brief command to determine which switch is the primary 
switch. This procedure upgrades the standby switch first, followed by the 
primary switch. Following this order reduces the reconvergence time to the 
minimum.
Upgrade Steps
Disable DCPDP if enabled:
On the secondary switch, disable DCPDP if enabled and save the 
configuration.
On the primary switch, disable DCPDP if enabled and save the 
configuration.
Upgrade the MLAG standby switch:
On the MLAG standby switch, shut down the MLAG-enabled physical 
links (not the port-channel).