Nortel Networks 4400 Manuel D’Utilisation

Page de 38
22    Configuring an MPANL tunneled through public frame relay
241-6401-280   6.0S1   
PROV> end prov
Verifying the MPANL connection
Once the provisioning is complete on both the 4400 and 6400, verify the link.
On the 4400
CLI> show msm linkstatus table 
IfIndex
: 149
InterfaceType : 
dte
LAPFStatus
: up
LocalComponentName : "MPA_1 MPANL/149"
RemoteComponentName: "PPNODE mpanl/5117 SigMpanl"
RemoteGenCfgType
: nortelAccessDevice
PANLStatus
: up
When the MPANL is up, the local and remote node names are displayed. 
The LAPF and PANL status display as up.
Note:  If using a 2.0 release, use the command:
CLI> show msm dtelinkstatus table
IfIndex
: 155
LAPFStatus
: up
LocalComponentName : "MPA_1 MPANL/155"
RemoteComponentName: "PPNODE mpanl/5117 SigMpanl"
On the 6400
> d lp/5 v35/1
Unlocked and enabled.
> d frmux/51
Unlocked and enabled.
> d frmux/51 lmi
Unlocked and enabled;
protocolStatus - normalCondition.
> d frmux/51 framer
Unlocked and enabled;
no errors displayed;
frames being sent to/from the interface.