Q-Logic 5802V Manuel D’Utilisation

Page de 412
14 – Command Reference
Hotreset
14-40
59263-01  A
S
Hotreset
Resets the switch for the purpose of activating the pending firmware without 
disrupting traffic. This command terminates all management sessions, saves all 
configuration information, and clears the event log. After the pending firmware is 
activated, the configuration is recovered. This process may take a few minutes. To 
save the event log to a file before resetting, enter the 
 Archive command.
Authority
Admin session
Syntax
hotreset
Notes
„
To ensure a successful non-disruptive activation, you should first satisfy the 
following conditions:
‰
No changes are being made to switches in the fabric including 
powering up, powering down, disconnecting or connecting ISLs, 
changing switch configurations, or installing firmware.
‰
No port on the switch is in the diagnostic state.
‰
No Zoning Edit sessions are open on the switch.
‰
No changes are being made to attached devices, including powering 
up, powering down, disconnecting, connecting, and HBA configuration 
changes.
‰
For a fabric in which one or more switches are running firmware prior 
to version 7.4, only one Enterprise Fabric Suite 2007 session can be 
open.
„
Install firmware on one switch at a time in the fabric. If you are installing 
firmware on one switch, wait two minutes after the activation is complete 
before installing firmware on a second switch.
„
Ports that change states during the non-disruptive activation, will be reset. 
When the non-disruptive activation is complete, Enterprise Fabric Suite 
2007 and QuickTools sessions reconnect automatically. However, Telnet 
sessions must be restarted manually.
„
This command clears the event log and all counters.
NOTE:
After upgrading firmware that includes changes to QuickTools, an open 
QuickTools session may indicate that the firmware is not supported. This 
means the new firmware is not supported by the previous QuickTools 
version. To correct this situation, close the QuickTools session and the 
browser window, then open a new QuickTools session.