Q-Logic 5802V Manuel D’Utilisation

Page de 412
14 – Command Reference
Show Port
59263-01  A
14-167
A
DecodeError
Number of decode errors detected
DownstreamISL
Downstream ISL state. True indicates a connection to another 
switch that is not the principal switch.
POSTFaultCode
Fault code from the most recent Power-on self test
POSTStatus
Status from the most recent Power-on self test
EpConnects
Number of times an E_Port connected through ISL negotia-
tion.
EpConnState
E_Port connection status
EpIsoReason
E_Port isolation reason
FBusy
Number of times the switch sent a F_BSY because Class 2 
frame could not be delivered within ED_TOV time. The num-
ber of class 2 and class 3 fabric busy (F_BSY) frames gener-
ated by this port in response to inbound frames. This usually 
indicates a busy condition on the fabric or N_Port that is pre-
venting delivery of this frame.
Flowerrors
Number of frames received there were no available credits.
FReject
Number of frames from devices that were rejected.
InvalidCRC
Invalid CRC detected.
InvalidDestAddr
Invalid destination address detected.
IOStreamGuard
I/O StreamGuard status
Licensed
Port activation status
LinkFailures
Number of optical link failures detected by this port. A link fail-
ure is a loss of synchronization or a loss of signal while not in 
the offline state. A loss of signal causes the switch to attempt 
to re-establish the link. If the link is not re-established, a link 
failure is counted. A link reset is performed after a link failure.
LinkSpeed
Port transmission speed
LinkState
Port activity status
LIP_AL_PD_ALPS
Number of F7, AL_PS LIPs, or AL_PD (vendor specific) 
resets, performed.
LIP_F7_AL_PS
This LIP is used to reinitialize the loop. An L_Port, identified by 
AL_PS, may have noticed a performance degradation and is 
trying to restore the loop.
Table 14-40. Show Port Parameters  (Continued)
Entry
Description