Setting the DMX Universes
  
On the web page go the DMX A or B Universe field and enter a universe number. Then 
click Submit. For Art-Net you may also select the DMX subnet and network switch. In 
Art-Net there are a possible 256 universes that are selected through 16 subnets which 
each contain 16 universes. So a unique combination of the subnet and universe 
numbers define what universe a port will transmit. More than one Net-IT can be 
configured to use the same unique universe. In E1.31 the universe number is directly 
selected as a single value from 1 to 65279. In Art-Net the Network Switch will cause the 
unit to use an IP address of 10.x.x.x when it is ON or 2.x.x.x when it is OFF. This is true 
only while the unit is still using the factory default IP address. If a full manual IP address 
is entered then the Network switch has no effect until a factory reset is performed. 
 
Reset Factory Defaults 
To reset the Net-IT to factory defaults (including IP address), use a paperclip to hold 
down the rest button for ten seconds. The display will show that it is resetting. 
 
Infotrace Name 
This name shows up on the display and also on the Infogate software window on the 
top right corner. This name can be changed only from Infogate. 
 
Art-Net Name 
This name is only shown when the Net-IT is configured for Art-Net. The name can be 
changed only from an Art-Net controller. 
 
Port Directions 
Currently the Net-IT only supports output of DMX and not input. The display will show 
both ports in an output state.