Back-UPS ES 550 & 750 
2
Install the PowerChute
®
 Personal Edition software
Using the supplied USB cable, connect the data port of the unit to the USB port on a computer. Install the 
PowerChute Personal Edition software using the enclosed CD.
Power-saving Master and Controlled Outlets
To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop computer or an A/V 
receiver, and Controlled peripheral devices, such as a printer, speakers, or a scanner. When the Master device goes 
into Sleep or Standby mode, or turns OFF, the Controlled device(s) will shut down as well, saving electricity.
Using the power-saving outlets
Note:
 The Back-UPS ships with the power saving feature DISABLED. To use this feature, the outlets 
must be enabled. 
Enable the power-saving outlets. 
Press and hold 
M
ASTER
 E
NABLE
 for 2 seconds. The unit will beep to indicate the 
feature is enabled. The green LED above the 
M
ASTER
 E
NABLE
 
button will illuminate.
Disable the power-saving outlets. 
Press and hold 
M
ASTER
 E
NABLE
 for two seconds. The unit will beep to 
indicated the feature is disabled. The green LED above the 
M
ASTER
 E
NABLE
 button will darken.
Setting the threshold
The amount of power used by a device in Sleep or Standby mode varies between devices. It may be necessary to 
adjust the threshold at which the Master outlet signals the Controlled outlets to shut down. When the threshold is set, 
the power-saving outlets are enabled.
1.Ensure a master device is connected to the Master outlet. Put that device into Sleep or Standby mode, or turn it 
OFF.
2.Press and hold the Master Enable button for six seconds. After the first 2 seconds the unit will beep, continue 
holding the button down until the unit three beeps times in a row. Release the Master Enable button. 
The Back-UPS unit will now recognize the threshold level of the Master device and save it as the new threshold 
setting.
Status Indicators
LED
Visual Indicator
Audible Alarm
Action
Power On - UPS is supplying conditioned utility 
power to the load.
Green LED - ON 
None
Not applicable.
On Battery - UPS is supplying battery power to the 
load connected to the Battery outlets.
Green LED - ON (off 
during beep) 
Beeping 4 times 
every 30 seconds
UPS transfers back to Power On 
operation, or when UPS is 
turned off.
Low Battery Warning - UPS is supplying battery 
power to the load connected to the Battery outlets and 
the battery is near exhaustion.
Green LED - flashing  Rapid beeping (every 
1/2 second)
UPS transfers back to normal 
operation, or when UPS is 
turned off.
Replace Battery is in need of charging or is at the end 
of its usual life and must be replaced
Green/Red alternating 
LED - flashing
Constant tone
UPS turned off with the power 
switch.
Battery Disconnected - The battery is disconnected or 
bad battery.
Red LED - flashing 
Constant tone
UPS turned off with the power 
switch.
Overload Shutdown - During On Battery operation a 
battery power supplied outlet overload was detected.
None
Constant tone
UPS turned off with the power 
switch.
Sleep Mode - During On Battery operation the battery 
power has been completely exhausted and the UPS is 
waiting for utility power to return to normal.
None
Beeping once every 4 
seconds.
Utility power is restored, or if 
utility power is not restored 
within 32 seconds, or the UPS is 
turned off.
Master Function Enabled
Master Enable LED - 
ON
None