APC BE700G Manuel D’Utilisation
Back-UPS ES 550 & 750
2
Install the PowerChute
®
Personal Edition software
Using the supplied USB cable, connect the data port of the unit to the USB port on a computer. Install the
PowerChute Personal Edition software using the enclosed CD.
PowerChute Personal Edition software using the enclosed CD.
Power-saving Master and Controlled Outlets
To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop computer or an A/V
receiver, and Controlled peripheral devices, such as a printer, speakers, or a scanner. When the Master device goes
into Sleep or Standby mode, or turns OFF, the Controlled device(s) will shut down as well, saving electricity.
receiver, and Controlled peripheral devices, such as a printer, speakers, or a scanner. When the Master device goes
into Sleep or Standby mode, or turns OFF, the Controlled device(s) will shut down as well, saving electricity.
Using the power-saving outlets
Note:
The Back-UPS ships with the power saving feature DISABLED. To use this feature, the outlets
must be enabled.
Enable the power-saving outlets.
Press and hold
M
ASTER
E
NABLE
for 2 seconds. The unit will beep to indicate the
feature is enabled. The green LED above the
M
ASTER
E
NABLE
button will illuminate.
Disable the power-saving outlets.
Press and hold
M
ASTER
E
NABLE
for two seconds. The unit will beep to
indicated the feature is disabled. The green LED above the
M
ASTER
E
NABLE
button will darken.
Setting the threshold
The amount of power used by a device in Sleep or Standby mode varies between devices. It may be necessary to
adjust the threshold at which the Master outlet signals the Controlled outlets to shut down. When the threshold is set,
the power-saving outlets are enabled.
adjust the threshold at which the Master outlet signals the Controlled outlets to shut down. When the threshold is set,
the power-saving outlets are enabled.
1.Ensure a master device is connected to the Master outlet. Put that device into Sleep or Standby mode, or turn it
OFF.
2.Press and hold the Master Enable button for six seconds. After the first 2 seconds the unit will beep, continue
holding the button down until the unit three beeps times in a row. Release the Master Enable button.
The Back-UPS unit will now recognize the threshold level of the Master device and save it as the new threshold
setting.
setting.
Status Indicators
LED
Visual Indicator
Audible Alarm
Action
Power On - UPS is supplying conditioned utility
power to the load.
power to the load.
Green LED - ON
None
Not applicable.
On Battery - UPS is supplying battery power to the
load connected to the Battery outlets.
load connected to the Battery outlets.
Green LED - ON (off
during beep)
during beep)
Beeping 4 times
every 30 seconds
every 30 seconds
UPS transfers back to Power On
operation, or when UPS is
turned off.
operation, or when UPS is
turned off.
Low Battery Warning - UPS is supplying battery
power to the load connected to the Battery outlets and
the battery is near exhaustion.
power to the load connected to the Battery outlets and
the battery is near exhaustion.
Green LED - flashing Rapid beeping (every
1/2 second)
UPS transfers back to normal
operation, or when UPS is
turned off.
operation, or when UPS is
turned off.
Replace Battery is in need of charging or is at the end
of its usual life and must be replaced
of its usual life and must be replaced
Green/Red alternating
LED - flashing
LED - flashing
Constant tone
UPS turned off with the power
switch.
switch.
Battery Disconnected - The battery is disconnected or
bad battery.
bad battery.
Red LED - flashing
Constant tone
UPS turned off with the power
switch.
switch.
Overload Shutdown - During On Battery operation a
battery power supplied outlet overload was detected.
battery power supplied outlet overload was detected.
None
Constant tone
UPS turned off with the power
switch.
switch.
Sleep Mode - During On Battery operation the battery
power has been completely exhausted and the UPS is
waiting for utility power to return to normal.
power has been completely exhausted and the UPS is
waiting for utility power to return to normal.
None
Beeping once every 4
seconds.
seconds.
Utility power is restored, or if
utility power is not restored
within 32 seconds, or the UPS is
turned off.
utility power is not restored
within 32 seconds, or the UPS is
turned off.
Master Function Enabled
Master Enable LED -
ON
ON
None