Agilent Technologies N5700 Manuel D’Utilisation

Page de 128
Protection Functions 
Series N5700 User’s Guide 
41 
Over-Temperature Protection 
The over-temperature protection circuit shuts down the power 
supply before the internal components can exceed their safe internal 
operating temperature. When an OTP condition occurs, the output is 
disabled, the display shows O7P, the PROT indicator blinks, and the 
OT status bit is set in the Questionable Condition status register. 
Resetting the OTP circuit can be automatic (non-latched) or manual 
(latched) depending on the Safe-Start or Auto-Restart mode. 
In Safe-Start mode, the OTP circuit is latched. The display continues 
to show O7P and the PROT indicator continues to blink. To reset the 
OTP circuit, press the OUT ON button. 
In Auto-Restart mode, the OTP circuit is non-latched. The power 
supply returns to its last setting automatically when the over-
temperature condition is removed. 
Power-Fail Protection 
If the AC power stops briefly, but returns before the power supply 
has reset, the power-fail protection circuit trips and the PF status bit 
is set in the Questionable Condition status register. Resetting the 
power-fail protection can be automatic (non-latched) or manual 
(latched), depending on the Safe-Start or Auto-Restart mode. 
In Safe-Start mode, the output of the power supply is Off, as specified 
by the reset state when AC power returns. In Auto-Restart mode, the 
power supply recovers its last settings when AC power returns. 
Front Panel Lock-Out 
The front panel controls can be locked to protect from accidental 
power supply parameter change. Press and hold the LIMIT button to 
toggle between Locked front panel and Unlocked front panel. The 
display will cycle between LFP and UFP. Releasing the LIMIT button 
while one of the modes is displayed, selects that mode.  
In Unlocked front panel mode, the front panel controls are enabled 
to program and monitor the power supply parameters.  
In Locked front panel mode, the VOLTAGE and CURRENT knobs, 
the OCP button, and the OUT ON button are disabled 
The power supply will not respond to attempts to use these controls. 
The display will show LFP to indicate that the front panel is locked. 
The OVP/UVL button remains active to preview the OVP and UVL 
setting. The LIMIT button also remains active to preview the output 
voltage and current setting or to unlock the front panel. 
NOTE 
This function operates independently of the SCPI SYST:COMM:RLST command. 
If the front panel has been locked from the front panel, it cannot be unlocked by 
SYST:COMM:RLST. Conversely, if the front panel has been locked by 
SYST:COMM:RLST, it cannot be unlocked from the front panel.