Analog Programming of Output Voltage and Current 
44 
Series N5700 User’s Guide  
In Auto-Restart mode, the power supply restores the operating 
settings that were saved when it was last turned off (see below). The 
output is either enabled or disabled according to its last setting.  
Output On/Off state 
UVL level 
Output voltage setting 
OCP setting 
Output current setting 
Locked/Unlocked front panel 
OVP level 
Start-up mode 
Daisy-Chained Output Shut-down 
It is possible to configure a multiple power supply system to shut 
down all the units when a fault condition occurs in one of the units. 
SW1 setup switch 5 must be in the Down position to enable the daisy-
chain operation. Other switches are unaffected by this setting. 
If a fault occurs in one unit, its Power Supply OK signal is set low and 
its display will indicate the fault. The other units shut off with their 
displays indicating SO. When the fault condition is cleared, all units 
will recover according to their Safe-Start or Auto-Restart settings. 
The following figure shows three units daisy-chained - the same 
connection method can be used with additional units. The Shut Off 
and Power Supply OK signals are referenced to Chassis Common (J1 
pins 2 and 3). 
Analog Programming of Output Voltage and Current 
CAUTION 
J1 pin 12, pin 22, and pin 23 are internally connected to the negative sense 
terminal. Do not reference these pins to any terminal other than the negative 
sense terminal, as it may damage the unit.  
In Local mode, the output voltage and current is programmed with 
the front panel VOLTAGE and CURRENT knobs or over the remote 
interface. In Analog mode, the output voltage and current can be 
programmed either by an analog voltage or by resistors connected to 
the rear panel J1 connector.  
The J1 connector also provides monitoring signals for the output 
voltage and output current. The programming range and monitoring 
signal range can be selected using the SW1 setup switch. 
POWER SUPPLY
#
1
J1-2,3 J1-16
J1-16
J1-16
J1-15
Supply OK
POWER SUPPLY
#
2
J1-2,3
J1-15
POWER SUPPLY
#3
J1-2,3
J1-15
Shut Off
Com
Shut Off
Supply OK
Com
Com
Supply OK
Shut Off