1. Trigger / Status Port Pin Identification – All signals are of  
 low voltage and current. DO NOT MISWIRE or damage may
  occur.
  +   Requires 5 -24VDC to activate the module with 5mA of
current. Note: The DCV can be supplied from any source.
The EVS protection requires the ETA-ECS6RM for operation.
  G  Circuit Ground, Must be of the same circuit as the DCV
source.
  V   AC Voltage Status Signal, this signal reports back to the 
ETA-ECS6RM the Incoming AC Mains Voltage to the ECM 
module.
  A   AC Current Status Signal, this signal reports back to the  
ETA-ECS6RM the AC Mains Current draw at the ECM 
module. Note: Not available on ETA-ECM20 type module.
  D   Fault Status Signal, reports to the ETA-ECS6RM fault 
conditions of an ECM module.
2. External Trigger / Manual On Switch – The ETA-ECM20M  
  has a manual override switch allowing it to be used as a local  
  Power Conditioner and Surge Suppressor. For it to be remotely  
  monitored and activated the switch must be in the “External  
  Trigger" position.
3. Incoming AC LED – This LED will illuminate Red when the
 ECM has incoming AC power present at the module. This LED
 must be On to operate. Note: If this LED is not illuminating
  check the following: 1) The unit is plugged in, 2) The AC Mains  
 Breaker feeding the AC leg to the ECM module is OFF, 3) The
  internal fuse has been damaged. This should only be inspected  
  by an authorized technician.
4. Active LED – This LED will illuminate Green when the ECM
 module has sensed the proper DCV to trigger activate the  
  power on circuit. Note: If connected to the ETA-ECS6RM and  
 the EVS circuit is activated this LED will not be ON. The
 Channel Status LED on the ETA-ECS6RM will flash indicating a  
  problem and will not turn the ECM module ON until the  
  AC Mains voltage is stable.
5. AC Fault LED – If damage to the Spike Suppression circuit   
 occurred this LED will illuminate Red. The module may still  
  operate but may not be protecting the items plugged into    
 the AC outlets. This LED will not turn off until repaired. Have
  the ECM module inspected by a qualified technician.  
  Note: Not available on ETA-ECM20 type module.
6. AC Mains Outlet – Two 120V AC 20A outlets.
WIRING THE ETA-ECM20M MODULE
The ETA-ECM20M is designed to be mated with the  
ETA-RACEWY6 housing and the ETA-ECS6RM controller. The 
specific job install AC power requirements and power distribution 
layout will dictate how the ETA-ECM20M modules are wired into 
the ETA-RACEWY6. Each ECM Module can be wired as a single 
20A run or in a parallel configuration as illustrated below. Each 
ECM module has dual 3-position screw terminal blocks that are in 
parallel and are clearly labeled as follows: 
E - Green = Ground  
L - Black = Load  
N - White = Neutral
Note: The above figures show the ECM wiring configuration 
of one 20A AC main line coming into an ETA-ECM20M, then 
paralleling with an ETA-ECM20 type module. 
Note: It appears that the wiring is in series but the ECM Module 
In/Out terminals are in parallel on the PCB. 