Varec 8620 Manuel D’Utilisation

Page de 34
8620 Driver Entry Terminal
Varec, Inc.
23
Host Communication
Environmental
Electrical
Mechanical Construction
Serial Ports
4
Communications type
Com 1, Com 3, and Com 4: RS-232
Com 2: RS-485/422 or RS-232
Ethernet
2
Operating Temperature
From -20 °C To 70 °C Ambient (From -4 °F To 158 °F Ambient)
Note The Smart Card Reader operates From -40 To 65 °C
(-35 To 150 °F)
Storage Temperature
From -40 °C To 70 °C (From -40 °F To 158 °F)
Humidity
5 - 95% non-Condensing at 0 °C To 55 °C (32 °F To 131 °F)
Operating Voltage
AC or DC
•  20 – 72 VDC
•  100 – 240 VAC 50/60 Hz
•  Supports 5 VDC throughout the 8620 DET
•  Units feature EMI/RFI Filtering, Load Regulation, and Over-
current Protection
Power Consumption DC
• 800 mA @ 24 VDC without Heater
• 3.4 A @ 24 VDC with Heater
Power Consumption AC
• 0.3 A @ 110 VAC without Heater
• 0.8 A @ 110 VAC with Heater
Enclosure Type
Rated NEMA 4X
Material
1/16” Thick Stainless Steel (1.5875 mm)
Dimensions
17.50" x 14.92" x 7.55" (445 x 380 x 192 mm)