Table 4.  DB-25 Pin Allocation 
(V.35) 
Pin Name 
Type 
1 SHIELD  
 
2 TxD-A 
Output 
3 RxD-A 
Input 
4 RTS-A 
Output 
5 CTS-A 
Input 
6 NC 
 
7 GND 
 
8  
 
9 RCLK-B 
Input 
10 NC 
 
11 NC 
 
12 TCLK-B 
Input 
13 NC 
 
14 TxD-B 
Output 
15 TCLK-A 
Input 
16 RxD-B 
Input 
17 RCLK-A 
Input 
18 NC 
 
19 NC 
 
20 NC 
 
21 NC 
 
22 NC 
 
23 NC 
 
24 NC 
 
25 NC 
 
Table 5.  DB-25 Pin Allocation 
(V.11) 
(used for RS-530, X.21, V.36) 
Pin Name 
Type 
1 SHIELD  
 
2 TxD-A 
Output 
3 RxD-A 
Input 
4 RTS-A 
Output 
5 CTS-A* 
Input 
6 NC 
 
7 GND 
 
8 NC 
 
9 RCLK-B 
Input 
10 NC 
 
11 NC 
 
12 TCLK-B 
Input 
13 CTS-B* 
Input 
14 TxD-B 
Output 
15 TCLK-A 
Input 
16 RxD-B 
Input 
17 RCLK-A 
Input 
18 NC 
 
19 RTS-B 
Output 
20 NC 
 
21 NC 
 
22 NC 
 
23 NC 
 
24 NC 
 
25 NC 
 
* Indication signal for X.21