Table 4-8.  SHDSL Status Screen Parameters 
Parameters Possible 
Values Description 
Op. State 
 
Idle 
Handshake
, Training, 
Framer Sync 
Data
 
Operational status of the SHDSL link 
Link is down 
FCD-IPM is establishing communication link with remote 
device 
Data is being transferred over the SHDSL link 
Bitrate 
 
Actual line rate after the handshake process is completed 
Loop Attenuation 
 
Difference (in dB) between the power transmitted from FCD-
IPM and the power received by the unit operating at the other 
side of the application 
Transmit Power 
 
Level of power (in dB) which is transmitted on the SHDSL line 
SNR 
 
Signal-to-noise ratio, difference (in dB) between signal and 
background noise 
SHDSL DSP Version, 
SHDSL Driver 
Version 
 
SHDSL DSP and driver revisions 
 
Loop Attenuation, Transmit Power and SNR are displayed only when OP. State is in 
Data mode. 
 
 
SHDSL STATUS  ( Device name - FCD-IPM ) 
 
  Op. State           : Data 
  Framer Status       : Sync 
  Bitrate             : 1032 
  Loop Attenuation    : 5 
  Transmit Power      : 7.5 
  SNR                 : 14 
  SHDSL DSP Version   : 1 
  SHDSL Driver Version: R1.7.1 
 
              CRC     ES    SES    LOSW   LOSWS   UAS 
  --------    ----   ----   ----   ----   -----   ---- 
  15 Min   :    3      1      0      0       0      0 
  24 hours :    0      0      0      0       0      0 
 
  ESC - previous menu  |  M - More  |  R - Refresh  |  C - Clear statistics  
Figure 4-40.  SHDSL Status 
Note