ZyXEL Communications 56K Plus Series Manuel D’Utilisation

Page de 66
                                                                                                          Omni 56K Plus Series User’s Guide 
Command Sets                                                                                                                                   4-19 
4.6 S-Register 
Descriptions 
In most bit-mapped S-registers, the default bit value is 0. Non-0 default values are followed by an 
asterisk. In some cases, default values are shown in the reference column preceded by +. Some bits are 
reserved for factory use and should not be changed. 
 
S-Register default values may vary depending on the country. 
Table 4-15 Basic S-Registers "ATSn=x" 
COMMAND 
FUNCTION & DESCRIPTION 
+REF. 
S0= 
Sets the number of rings on which the modem will answer.  0 value disables 
auto-answer. 
+000 
S1= 
Counts and stores number of rings from an incoming call. 
+000 
S2= 
Defines escape code character, default ‘+’  (43 dec.). A value of 128-255 
disables the escape code. 
+043 
S3= 
Defines ASCII Carriage Return. 
+013 
S4= 
Defines ASCII Line Feed. 
+010 
S5= 
Defines ASCII Backspace. A value of 128-255 disables the Backspace key’s 
delete function. 
+008 
S6= 
Sets the number of seconds the modem waits before dialing if ‘X0’ or ‘X1’ is 
selected. If a setting of ‘X2,’ ‘X7’ is selected, the modem will dial as soon as it 
detects a dial tone. This register also sets the time-out interval for the “W” dial 
modifier to wait for the dial tone. (See also S41b4) 
+003 
S7= 
Sets duration, in number of seconds modem waits for a carrier. 
+060 
S8= 
Sets duration, in seconds, for pause (,) option in Dial command and pause 
between command re-executions for Repeat (>) command. 
+002 
S9= 
Sets duration, in tenths of a second of remote carrier signal before recognition. 
(Ignored if in non-FSK or half-duplex operation) 
+006 
S10= 
Sets duration, in tenths of a second, modem waits after loss of carrier before 
hanging up. 
+007 
S11= 
Sets duration and spacing, in milliseconds, of dialed Touch-Tones. 
+070 
 
Table 4-16 Extended S-Registers "ATSn=x" 
COMMAND BIT  DEC  HEX 
FUNCTION 
AND 
DESCRIPTION 
REF. 
S13= 
bit dec hex Bit-mapped 
register. 
+000 
 
Capture modem manufacturer information during V.42 
handshake, can be displayed at ATI2 <Last 
Speed/Protocol> line if available (‘Flash’ or ‘ ZyXEL’ 
stands for ZyXEL connection) 
 
S14= 
bit dec hex Bit-mapped 
register: 
+002 
 
Grant Remote Digital Loop-back test request. 
&T4 
 
 
Deny Remote Digital Loop-back test request. (Default) 
&T5* 
S15= 
bit dec hex Bit-mapped 
register. 
+066