ADC UTU-701C Manuel D’Utilisation

Page de 82
Overview
  
700-701-100-02
6
August 9, 2002
 UTU-701 and ETU-751 List 1
 defines the system states indicated by the front panel LEDs. When power is applied to the unit, one of the 
LEDs listed in 
will always be on.
Table 4.
Line and Desktop Unit Front Panel LED Indications
LED
Mode
Description
HDSL SYNC LED
Steady green 
Slow blinking 
Off
HDSL loop is ready to transmit and receive data across all spans. 
HDSL loop acquisition is in progress for local span. 
HDSL loop is not configured. 
HDSL ALM LED
Steady red 
Pulsing red 
Off
Loss of sync word (LOSW); or the margin is below the set margin 
alarm threshold; or Errored Seconds (ES) count is above 
threshold on any span. 
Pulses for every ES on any span. 
Normal transmit or receive data is in progress.
I/F ALM LED
Steady red
Loss of Signal (LOS) alarm due to loss of G.703 signal or Loss of 
Clock (LOC) alarm due t
o
 loss of external clock (when using EXT 
timing).
LPBK LEDs 
(a)
LOC
REM
Steady yellow
Off
Local HDSL analog loopback is active.
Off
Off
No loopbacks are active.
Blinking yellow
Off
Local interface loopback is active.
 Off
Steady yellow
Remote loopback is active.
Blinking yellow
Blinking yellow A loopback away from the local equipment is active.
(a)
 The LOC and REM LPBK LEDs are read in unison.