ADC UTU-701C Manuel D’Utilisation

Page de 82
700-701-100-02
 Testing
UTU-701 and ETU-751 List 1
August 9, 2002
 61
Table 30.
Test Menu Options
Operating Option
Default Setting
Network Diagram
Shows the loopback position and direction when the loopback is enabled and active.
Lpbk Dir
Selects one of three loopback direction modes:
OFF
No loopbacks are active.
NETWORK
The loopback selected in Loopback Position is directed toward the network equipment connected to 
the LTU.
CUSTOMER
The loopback selected in Loopback Position is directed toward the customer's equipment connected 
to the NTU.
Lpbk Loop(s)
Selects the loops used in the loopback test:
NONE
Option not available with single-pair HDSL card.
Lpbk Position
Selects the possible loopback positions:
NONE
Option not available with single-pair HDSL card.
Lpbk Timeout
Selects one of three loopback timeouts:
NONE
Disables automatic timeout cancellation of all loopbacks.
20
Automatically cancels any loopback 20 minutes after initiation.
120
Automatically cancels any loopback 120 minutes after initiation.
Table 31.
BER Section of Test Menu
Field
Description
BER Test
Selects the state of the BER test.
STOP
Terminates the current test and resumes normal transmission of user payload. Prior BER tests are 
maintained for reference on the screen. STOP must be selected to terminate the BER test prior to exiting 
the screen.
RESTART
Begins BER test. This disrupts user payload traffic and inserts a pseudo-random bit sequence (PRBS) 
at the LTU toward the NTU. The actual pattern used is a 2x10
15
 pattern as defined by reselecting this 
option (pressing the 
 key) while the test is running. This entry reinitiates the BER values and 
restarts the test.
Det. Status
Displays the current status of the BER detector at the LTU.
NOT ACTIVE
Displays while the BER is not running.
SYNCING
Indicates that the BER qualification period is in progress (128 received bits are compared to the PRBS).
IN SYNC
Indicates that the BER test is in progress. The BER meter accumulates errors once per test interval (16 
seconds). In a high bit error environment the test interval is shortened and the BER meter is updated 
every second.
Test Time
Displays the elapsed test time for the BER test.
Bit Errors
Displays the number of bits received that did not match the PRBS pattern. This field is updated every 
30 seconds, with a maximum value of 255 per update.
BER
Displays the Bit Error Rate computer for the current test. This field is updated very 16 seconds, as is 
displayed in exponential form. The lowest positive displayable value is 1x10
-11
ENTER