RAD Data comm IPmux-11 Manuel D’Utilisation

Page de 148
Chapter 1  Introduction 
Installation and Operation Manual 
1-10 
Functional Description 
IPmux-11 Ver. 2.00 
VLAN Support 
VLAN, according to IEEE 802.1p&Q, adds four bytes to the MAC layer of the 
Ethernet frame. The user can set the contents of these bytes, MAC layer priority 
and VLAN ID. In this mode, only VLAN format frames are sent and received by 
IPmux-11. 
 shows the VLAN tag format.  
802.1D Tag Protocol Type
81
00
user_priority
CF
I =
 0
VID
8
6
5
4
1
8
1
Priority
VLAN ID
 
Figure 1-7.  VLAN Tag Format (802.1p&Q) 
UDP Support 
Table 1-3.  UDP Ports Definition 
Field Length (Bits)  Field Description 
Value 
Function 
2 bytes 
UDP Source Port   
2–497d*  Destination timeslots bundle 
2 bytes 
UDP Destination Port    2142d 
Standard TDMoIP UDP port 
* The MSB of this field can be either 1 or 0 for inband end-to-end proprietary signaling.  
 
The UDP Source Port field is used for destination timeslots bundle indication. 
 
For more information about VLAN tagging, refer to IEEE standard 802.1p&Q.  
TDMoMPLS 
 illustrate TDMoMPLS frame structure.  
CRC 
TDM Payload 
CW 
MPLS 
ETH 
Figure 1-8.  TDMoMPLS Frame Structure 
Note