Site Requirements and Prerequisites 
2-1 
Chapter 2 
Installation and Setup 
2.1 Introduction 
This chapter describes installation and setup procedures for the IPmux-11 unit.  
After installing the unit, refer to 
If a problem is encountered, refer to 
 for test and diagnostic instructions. 
 
 
Internal settings, adjustment, maintenance, and repairs may be performed 
only by a skilled technician who is aware of the hazards involved. 
Always observe standard safety precautions during installation, operation, and 
maintenance of this product. 
 
2.2  Site Requirements and Prerequisites 
The IPmux-11 device is intended for installation on desktop, 19-inch racks and 
walls. All the connections are made at the rear panel. A hardware kit (RM-33-2) for 
mounting one or two IPmux-11 units into a 19-inch rack is available from RAD. 
Drilling template for wall installation is provided at the end of the manual.  
AC-powered IPmux-11 units should be installed within 1.5m (5 ft) of an 
easily-accessible grounded AC outlet capable of furnishing the voltage in 
accordance with IPmux-11 nominal supply voltage. 
DC-powered IPmux-11 units require a -48 VDC power source, which must be 
adequately isolated from the main supply.  
Allow at least 90 cm (36 in) of frontal clearance for operating and maintenance 
accessibility. Allow at least 10 cm (4 in) clearance at the rear of the unit for signal 
lines and interface cables. 
The ambient operating temperature of IPmux-11 should be 0 to 50°C (32 to 
122°F), at a relative humidity of up to 90%, non-condensing. 