Configuration Sequence 
4-1 
Chapter 4 
Configuration 
This chapter illustrates the IPmux-11 configuration screens and explains their 
parameters.  
Menu trees of the IPmux-11 management software are shown in 
4.1 Configuration Sequence 
There are four basic configuration steps that need to be followed when deploying 
any IPmux unit: 
1.  IP configuration – Setting the device host IP address and the manager IP address. 
2.  Physical layer configuration – Setting the TDM parameters (line type, clocking, 
etc.) according to the application requirements and topology. 
3.  Creating bundles – Allocating timeslots to bundles  
4.  Connecting bundles – Directing the bundles defined above to remote IPmux 
unit. 
IPmux-11 can be managed by a network management station that is located on  
the LAN connected to the one of the unit’s Ethernet ports. In order to establish a 
proper connection, it is necessary to configure IPmux with a basic configuration. 
 
To perform preliminary IPmux configuration: 
1.  Connect an ASCII terminal to the RS-232 control port of IPmux. 
2.  Log in as Superuser (su). 
3.  Assign an IP address to IPmux. 
4.  Assign a subnet mask and a default gateway. 
5.  You can also enable or disable the IPmux DHCP client. 
6.  Set read, trap, and read/write communities to public. 
7.  Set a manager IP address and location. 
8. Reset IPmux. 
 
Make sure that you save your settings at each configuration screen. 
 