RAD Data comm IPmux-11 Manuel D’Utilisation

Page de 148
Chapter 4  Configuration 
Installation and Operation Manual 
4-10 
Configuring IPmux-11 for Management 
IPmux-11 Ver. 2.00 
 
Enable (Telnet, SNMP or Web access is enabled) 
 
Disable (Telnet, SNMP or Web access is disabled) 
 
Manager Only (Access is allowed only for the stations appearing in the 
manager list). 
Table 4-1.  Management Access Implementation 
Who is Allowed to Access IPmux-11 
Access Method 
Mode  
Network 
Manager(s) 
Defined  
Network 
Manager(s) not 
Defined  
Enable Anybody 
Anybody 
Disable Nobody 
Nobody 
SNMP Access 
Manager Only 
Only defined 
network managers 
Nobody 
Enable Anybody 
Anybody 
Disable Nobody 
Nobody 
Telnet Access 
Manager Only 
Only defined 
network managers 
Anybody 
Enable Anybody 
Anybody 
Disable Nobody 
Nobody 
Web Access 
Manager Only 
Only defined 
network managers 
Anybody 
 
Configuration>System>Management>Management Access 
1. User Access 
 
2. TELNET access 
 
>  (Enable) 
3. SNMP access 
 
>  (Disable) 
4. WEB access 
 
>  (Enable) 
 
 
ESC-prev.menu; !-main menu; &-exit 
              1 Mngr/s 
Figure 4-10.  Management Access Menu 
Configuring Control Port Parameters 
Configuration parameters of the IPmux-11 control port, except for the baud rate 
are set at the factory and cannot be changed by the user (see 
). These 
parameters have the following values:  
•  Data bits – 8 
•  Parity – None 
•  Stop bits – 1 
•  Flow control – None.