RAD Data comm IPmux-11 Manuel D’Utilisation

Page de 148
Chapter 5  Configuring IPmux-11 for a Typical Application 
Installation and Operation Manual 
5-4 
Configuring IPmux-11 Units
 
IPmux-11 Ver. 2.00 
Configuring Bundles 
 
To assign timeslots to a bundle: 
1.  Display the Connection menu (Configuration > Connection), and assign a 
number 1 to a bundle. 
2.  Display the DS0 Bundle Configuration menu (Configuration > Connection > 
DS0 bundle
), and assign timeslots 1 to 10 to bundle 1. 
Configuration>Connection>DS0 bundle configuration 
 
         +1     +2     +3     +4     +5     +6     +7     +8     +9     +10 
  TS  0  1      1      1      1      1      1      1      1      1      1 
  TS 10  0      0      0      0      0      0      0      0      0      0 
  TS 20  0      0      0      0      0      0      0      0      0      0 
  TS 30  0 
 
 1. Change cell [0 - 1]           ... (0) 
>
  
 
Please select item <1 to 1> 
E - Enable All; L - Disable All 
ESC-prev.menu; !-main menu; &-exit; ?-help                           1 Mngr/s 
Figure 5-5.  Assigning Timeslots to a Bundle 
 
To connect the bundles: 
1.  Display the Bundle Connection Configuration menu (Configuration > 
Connection 
Bundle connection) and configure the following parameters: 
 
Destination IP address for IPmux-11 (A) bundle –192.168.10.1 
 
Destination IP address for IPmux-11 (B) bundle  – 192.168.10.2 
 
Connection status – Enable 
 
Destination bundle – 1 
 
Jitter buffer – 5 msec 
 
OAM Enabled. 
2.  Leave all other parameters with their default values. 
3.  Save the changes.