Installation
User Manual
5
21
2
Installation
2.1
Components
Ensure that you have all required components:
•
Micro Motion EtherNet/IP Module
•
Power connector
•
Micro Motion EtherNet/IP Resource CD
-
Micro Motion EtherNet/IP Module User Manual
-
EDS file
-
Micro Motion Ethernet Config Tool
•
Configuration cable
•
Modbus serial cable and connector (included)
•
Ethernet cable and connector (not included)
2.2
Device installation
1.
If you are using the EtherNet/IP Module with a transmitter, mount the transmitter and
wire it to the sensor and to power.
wire it to the sensor and to power.
2.
If you are using a Micro Motion MVD Direct Connect flowmeter, mount and wire the
core processor and barrier. See the following illustration to identify the barrier
terminals.
core processor and barrier. See the following illustration to identify the barrier
terminals.
44 (RS-485/B)
43 (RS-485/A)
42 (VDC +)
41 (VDC –
43 (RS-485/A)
42 (VDC +)
41 (VDC –
14 (RS-485/B)
13 (RS-485/A)
12 (VDC +)
11 (VDC –
13 (RS-485/A)
12 (VDC +)
11 (VDC –
I.S. terminals
for connection to core
processor
processor
Non-I.S. terminals
for connection to remote
host and power supply
host and power supply
Barrier