Emerson P/N MMI-20019808 Manuel D’Utilisation

Page de 78
 
14
Micro Motion EtherNet/IP Module
Basic Network Configuration
To set the IP address, see the following table.
 
Ethernet Config Tool
See the Anybus Communicator manual for instructions.
 
IMPORTANT
If you change the network settings using the Ethernet Config Tool, you will not be able to use 
the Micro Motion web pages to change network settings in the future. All future changes to 
network settings must beperformed using the Ethernet Config Tool. 
ethcfg.cfg file
To set the network settings using the \ethcfg.cfg file:
1.
Set all configuration switches on the device to OFF.
2.
Make a connection to the device from the Ethernet Config Tool and disable TCP/IP 
Settings
 (Fieldbus parameter section). Alternatively, you can access the TCP/IP 
parameters using the TCP/IP Interface Object.
Table 3-1  Network settings, locked
Parameter
Value
IP address
192.168.0.x
where x is determined by the switches
Gateway
192.168.0.255
Subnet
255.255.255.0
DHCP
OFF
Table 3-2  Network settings using switches
Switch
IP address
1
2
3
4
5
6
7
8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
192.168.0.1
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
192.168.0.2
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
192.168.0.3
...
...
...
...
...
...
...
...
...
ON
ON
ON
ON
ON
ON
ON
OFF
192.168.0.254
ON
ON
ON
ON
ON
ON
ON
ON
Invalid