Device Profile
User Manual
 
47
B.3.9
Input assembly for petroleum measurement configuration
Byte
Access
Name
Type
Notes
0–3
Get
Mass flow rate
Float
4–7
Get
Density
Float
8–11
Get
Temperature
Float
12–15
Get
Volume flow rate (liquid 
volume)
Float
16–19
Get
Mass total
Float
20–23
Get
Volume total
Float
24–27
Get
Drive gain
Float
28–29
Get
Status word
U16 or Word
• For Model 1700 Analog, Model 2700 
Analog, Model 1500 Analog, Model 
2500, and all Series 3000 transmitters: 
SNS Status Word 1 (see Section B.7.1)
• For MVD Direct Connect and 9739 MVD 
transmitters: SNS Status Word 2 (see 
Section B.7.2)
30-31
Get
Status word
U16 or Word
• For Model 1700 Analog, Model 2700 
Analog, Model 1500 Analog, Model 
2500, and all Series 3000 transmitters: 
SNS Status Word 2 (see Section B.7.2)
• For MVD Direct Connect and 9739 MVD 
transmitters: SNS Status Word 1 (see 
Section B.7.1)
32–35
Get
Temperature-corrected 
density
Float
36–39
Get
CTL
Float
40–43
Get
Temperature-corrected 
volume flow
Float
44–47
Get
Temperature-corrected 
volume total
Float
48–51
Get
Temperature-corrected 
volume inventory
Float
52–55
Get
Average temperature-
corrected density
Float
56–59
Get
Average temperature
Float