Debugger Engine Commands
Debugger Commands
753
Microcontrollers Debugger Manual 
The COLUMNWIDTH command sets the width of one column entry on the right 
pane of the Inspector Window. The first parameter (columnname) specifies which 
column. The following column names currently exist:
• Names - simple name list
• Interrupts - interrupt list
• SymbolTableFunction - function in the Symbol Table
• ObjectPoolObject - Object in Object Pool without additional information
• Events - event list
• Components - component list
• SymbolTableVariable - variable or differentiation in the Symbol Table
• ObjectPoolIOBase - Object in Object Pool with additional information
• SymbolTableModules - non IOBase derived Object in the Object Pool
The column field is the name of the specific field, which is also displayed in the 
Inspector Window.
The following commands set the width of the function names to 100:
inspect < ATTRIBUTES COLUMNWIDTH SymbolTableModules Name 
100
NOTE
Due to the “inspect <“ redirection, only the Inspector handles this command.
The EXPAND command computes and displays all subitems of a specified item up 
to a given depth. An item is specified by specifying the complete path starting at 
one of the root items like “Symbol Table” or “Object Pool”. Names with spaces 
must be surrounded by double quotes.
To expand all subitems of TargetObject in the Object Pool up to four levels, 
the following command can be used:
inspect < ATTRIBUTES EXPAND “Object Pool” TargetObject 4
NOTE
Because the name Object Pool contains a space, it must be surrounded by 
double quotes.
NOTE
The symbol Table, Stack or other Items may have recursive information. So it 
may occur that the information tree grows with the depth. Therefore, 